{"id":5133,"date":"2026-10-22T01:08:19","date_gmt":"2026-10-22T01:08:19","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=5133"},"modified":"2026-10-22T01:11:29","modified_gmt":"2026-10-22T01:11:29","slug":"u-1000-r2v","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/","title":{"rendered":"U-1000 R2V"},"content":{"rendered":"<div id=\"unima-r2v-overview\">\n<style>\n#unima-r2v-overview {\n  --navy:#102e4a;\n  --blue:#0875bb;\n  --pale:#eaf4fb;\n  --line:#d8e5ef;\n  font-family:Arial,Helvetica,sans-serif;\n  color:#25394b;\n  width:100%;\n  margin:0 auto 30px;\n}\n#unima-r2v-overview * {box-sizing:border-box}\n#unima-r2v-overview .r2v-hero {\n  background:linear-gradient(125deg,#102e4a,#174f7c);\n  color:#fff;\n  padding:32px 35px;\n  border-radius:12px 12px 0 0;\n}\n#unima-r2v-overview .r2v-eyebrow {\n  color:#8bd6ff;\n  font-size:12px;\n  font-weight:700;\n  letter-spacing:2px;\n  text-transform:uppercase;\n}\n#unima-r2v-overview h2 {\n  font-size:32px;\n  line-height:1.15;\n  margin:12px 0 10px;\n  color:#fff;\n  font-weight:800;\n}\n#unima-r2v-overview .r2v-subtitle {\n  font-size:16px;\n  line-height:1.6;\n  color:#dcecf8;\n  margin:0;\n}\n#unima-r2v-overview .r2v-content {\n  border:1px solid var(--line);\n  border-top:0;\n  padding:28px;\n  background:#fff;\n  border-radius:0 0 12px 12px;\n}\n#unima-r2v-overview .r2v-intro {\n  font-size:15px;\n  line-height:1.8;\n  margin:0 0 25px;\n}\n#unima-r2v-overview .r2v-facts {\n  display:grid;\n  grid-template-columns:repeat(4,minmax(0,1fr));\n  gap:12px;\n  margin-bottom:28px;\n}\n#unima-r2v-overview .r2v-fact {\n  background:var(--pale);\n  padding:17px 12px;\n  text-align:center;\n  border-radius:8px;\n  border-bottom:3px solid var(--blue);\n}\n#unima-r2v-overview .r2v-fact strong {\n  display:block;\n  color:var(--navy);\n  font-size:20px;\n  margin-bottom:6px;\n}\n#unima-r2v-overview .r2v-fact span {\n  display:block;\n  color:#50697e;\n  font-size:12px;\n}\n#unima-r2v-overview .r2v-grid {\n  display:grid;\n  grid-template-columns:repeat(2,minmax(0,1fr));\n  gap:22px;\n}\n#unima-r2v-overview .r2v-panel {\n  border:1px solid var(--line);\n  border-radius:8px;\n  overflow:hidden;\n  min-width:0;\n}\n#unima-r2v-overview .r2v-panel h3 {\n  background:var(--navy);\n  color:#fff;\n  font-size:15px;\n  padding:13px 17px;\n  margin:0;\n}\n#unima-r2v-overview table {\n  width:100%;\n  border-collapse:collapse;\n  table-layout:fixed;\n  margin:0;\n}\n#unima-r2v-overview td {\n  padding:11px 13px;\n  font-size:13px;\n  line-height:1.45;\n  vertical-align:top;\n  border-bottom:1px solid var(--line);\n  overflow-wrap:anywhere;\n}\n#unima-r2v-overview tr:nth-child(even) td {\n  background:#f2f8fc;\n}\n#unima-r2v-overview td:first-child {\n  color:#12669c;\n  font-weight:700;\n  width:46%;\n}\n#unima-r2v-overview .r2v-section {\n  margin-top:25px;\n}\n#unima-r2v-overview .r2v-section h3 {\n  font-size:18px;\n  color:var(--navy);\n  border-left:4px solid var(--blue);\n  padding-left:12px;\n  margin:0 0 15px;\n}\n#unima-r2v-overview .r2v-apps {\n  display:grid;\n  grid-template-columns:repeat(2,minmax(0,1fr));\n  gap:10px;\n}\n#unima-r2v-overview .r2v-app {\n  background:#f0f7fc;\n  padding:12px 15px;\n  border-radius:6px;\n  font-size:13px;\n  line-height:1.5;\n}\n#unima-r2v-overview .r2v-app:before {\n  content:\"\u2713\";\n  color:var(--blue);\n  font-weight:800;\n  margin-right:9px;\n}\n#unima-r2v-overview .r2v-note {\n  margin-top:24px;\n  background:#f1f7fc;\n  border-left:4px solid var(--blue);\n  padding:15px 18px;\n  font-size:12px;\n  line-height:1.7;\n}\n@media(max-width:767px) {\n  #unima-r2v-overview .r2v-hero {padding:25px 20px}\n  #unima-r2v-overview h2 {font-size:27px}\n  #unima-r2v-overview .r2v-content {padding:18px}\n  #unima-r2v-overview .r2v-facts {\n    grid-template-columns:repeat(2,minmax(0,1fr));\n  }\n  #unima-r2v-overview .r2v-grid,\n  #unima-r2v-overview .r2v-apps {\n    grid-template-columns:1fr;\n  }\n}\n<\/style>\n\n<div class=\"r2v-hero\">\n  <div class=\"r2v-eyebrow\">UNIMA CABLE | POWER CABLES<\/div>\n  <h2>U-1000 R2V<\/h2>\n  <p class=\"r2v-subtitle\">\n    Low Voltage Power Cable | XLPE Insulation |\n    PVC Outer Sheath | 0.6\/1 kV\n  <\/p>\n<\/div>\n\n<div class=\"r2v-content\">\n  <p class=\"r2v-intro\">\n    U-1000 R2V is a low-voltage power cable designed for\n    electrical energy distribution in industrial facilities,\n    buildings, urban networks and fixed installations.\n    Its copper conductors, XLPE insulation and PVC outer\n    sheath provide reliable operation at conductor temperatures\n    up to 90\u00b0C, with resistance to sunlight and atmospheric\n    conditions.\n  <\/p>\n\n  <div class=\"r2v-facts\">\n    <div class=\"r2v-fact\">\n      <strong>0.6\/1 kV<\/strong>\n      <span>Radni napon<\/span>\n    <\/div>\n    <div class=\"r2v-fact\">\n      <strong>90\u00b0C<\/strong>\n      <span>Max. Operating Temperature<\/span>\n    <\/div>\n    <div class=\"r2v-fact\">\n      <strong>250\u00b0C<\/strong>\n      <span>Short-Circuit Temperature<\/span>\n    <\/div>\n    <div class=\"r2v-fact\">\n      <strong>Eca<\/strong>\n      <span>CPR Classification<\/span>\n    <\/div>\n  <\/div>\n\n  <div class=\"r2v-grid\">\n    <div class=\"r2v-panel\">\n      <h3>Cable Construction<\/h3>\n      <table>\n        <tbody>\n          <tr><td>Conductor<\/td><td>Copper, Class 1 or Class 2<\/td><\/tr>\n          <tr><td>Conductor Standard<\/td><td>EN 60228<\/td><\/tr>\n          <tr><td>Insulation<\/td><td>XLPE Compound<\/td><\/tr>\n          <tr><td>Bedding<\/td><td>Extruded elastomeric or plastomeric compound, or plastic tape<\/td><\/tr>\n          <tr><td>Outer Sheath<\/td><td>PVC Compound<\/td><\/tr>\n          <tr><td>Sheath Colour<\/td><td>Crna<\/td><\/tr>\n          <tr><td>Core Identification<\/td><td>HD 308 S2<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"r2v-panel\">\n      <h3>Technical Characteristics<\/h3>\n      <table>\n        <tbody>\n          <tr><td>Radni napon<\/td><td>0.6\/1 kV<\/td><\/tr>\n          <tr><td>Test Voltage<\/td><td>4 kV<\/td><\/tr>\n          <tr><td>Operating Temperature<\/td><td>Up to +90\u00b0C<\/td><\/tr>\n          <tr><td>Short-Circuit Temperature<\/td><td>Up to +250\u00b0C<\/td><\/tr>\n          <tr><td>Minimum Laying Temperature<\/td><td>-5\u00b0C<\/td><\/tr>\n          <tr><td>Bending Radius \u2013 Multicore<\/td><td>12 \u00d7 D<\/td><\/tr>\n          <tr><td>Bending Radius \u2013 Single-Core<\/td><td>15 \u00d7 D<\/td><\/tr>\n          <tr><td>Standardi<\/td><td>NF C 32-321 \/ IEC 60502-1<\/td><\/tr>\n          <tr><td>CPR razred<\/td><td>Eca<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n  <\/div>\n\n  <div class=\"r2v-section\">\n    <h3>Typical Applications<\/h3>\n    <div class=\"r2v-apps\">\n      <div class=\"r2v-app\">Low-voltage power distribution<\/div>\n      <div class=\"r2v-app\">Industrial electrical installations<\/div>\n      <div class=\"r2v-app\">Commercial and residential buildings<\/div>\n      <div class=\"r2v-app\">Urban distribution networks<\/div>\n      <div class=\"r2v-app\">Outdoor fixed installations<\/div>\n      <div class=\"r2v-app\">Cable trays, walls and raceways<\/div>\n      <div class=\"r2v-app\">Protected underground installations<\/div>\n      <div class=\"r2v-app\">Installations requiring resistance to sunlight and weather<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"r2v-note\">\n    <strong>Installation Note:<\/strong>\n    Direct underground installation requires suitable\n    mechanical protection. Prolonged installation in\n    waterlogged ground is not recommended.\n    Cable dimensions, conductor resistance and weights\n    depend on the selected configuration.\n  <\/div>\n<\/div>\n<\/div>\n\n\n\n<div id=\"unima-r2v-dimensions\">\n<style>\n#unima-r2v-dimensions {\n  --navy:#102e4a;\n  --blue:#0875bb;\n  --pale:#eaf4fb;\n  --line:#d8e5ef;\n  font-family:Arial,Helvetica,sans-serif;\n  color:#25394b;\n  width:100%;\n  margin:0 auto 30px;\n}\n#unima-r2v-dimensions * {\n  box-sizing:border-box;\n}\n#unima-r2v-dimensions .r2v-head {\n  background:linear-gradient(125deg,#102e4a,#174f7c);\n  padding:27px 30px;\n  border-radius:12px 12px 0 0;\n  color:#fff;\n}\n#unima-r2v-dimensions .r2v-label {\n  font-size:12px;\n  font-weight:700;\n  letter-spacing:1.5px;\n  color:#9bd9ff;\n  text-transform:uppercase;\n}\n#unima-r2v-dimensions h2 {\n  color:#fff;\n  font-size:27px;\n  font-weight:800;\n  margin:9px 0;\n  line-height:1.2;\n}\n#unima-r2v-dimensions .r2v-head p {\n  color:#dcecf8;\n  font-size:14px;\n  margin:0;\n  line-height:1.6;\n}\n#unima-r2v-dimensions .r2v-body {\n  background:#fff;\n  border:1px solid var(--line);\n  border-top:0;\n  padding:23px;\n  border-radius:0 0 12px 12px;\n}\n#unima-r2v-dimensions .r2v-stats {\n  display:grid;\n  grid-template-columns:repeat(3,minmax(0,1fr));\n  gap:12px;\n  margin-bottom:22px;\n}\n#unima-r2v-dimensions .r2v-stat {\n  background:var(--pale);\n  border-bottom:3px solid var(--blue);\n  border-radius:7px;\n  padding:16px 10px;\n  text-align:center;\n}\n#unima-r2v-dimensions .r2v-stat strong {\n  display:block;\n  font-size:21px;\n  color:var(--navy);\n  margin-bottom:5px;\n}\n#unima-r2v-dimensions .r2v-stat span {\n  font-size:12px;\n  color:#526b7f;\n}\n#unima-r2v-dimensions .r2v-table-wrap {\n  width:100%;\n  overflow-x:auto;\n  border:1px solid var(--line);\n  border-radius:8px;\n}\n#unima-r2v-dimensions table {\n  width:100%;\n  border-collapse:collapse;\n  min-width:680px;\n  margin:0;\n}\n#unima-r2v-dimensions thead th {\n  background:#125084;\n  color:#fff;\n  font-size:12px;\n  font-weight:700;\n  padding:14px 10px;\n  text-align:center;\n  line-height:1.4;\n  border-right:1px solid #437da8;\n}\n#unima-r2v-dimensions thead th:first-child {\n  text-align:left;\n}\n#unima-r2v-dimensions tbody td {\n  font-size:13px;\n  padding:11px 10px;\n  border-bottom:1px solid var(--line);\n  text-align:center;\n}\n#unima-r2v-dimensions tbody td:first-child {\n  text-align:left;\n  font-weight:700;\n  color:#07518a;\n  white-space:nowrap;\n}\n#unima-r2v-dimensions tbody tr:nth-child(odd) {\n  background:#edf6fc;\n}\n#unima-r2v-dimensions tbody tr:nth-child(even) {\n  background:#fff;\n}\n#unima-r2v-dimensions tbody tr:hover {\n  background:#dceef9;\n}\n#unima-r2v-dimensions .r2v-note {\n  background:#f1f7fc;\n  border-left:4px solid var(--blue);\n  padding:14px 17px;\n  margin-top:20px;\n  font-size:12px;\n  line-height:1.7;\n}\n@media(max-width:767px) {\n  #unima-r2v-dimensions .r2v-head {\n    padding:22px 18px;\n  }\n  #unima-r2v-dimensions h2 {\n    font-size:23px;\n  }\n  #unima-r2v-dimensions .r2v-body {\n    padding:15px;\n  }\n  #unima-r2v-dimensions .r2v-stats {\n    gap:7px;\n  }\n  #unima-r2v-dimensions .r2v-stat {\n    padding:12px 5px;\n  }\n  #unima-r2v-dimensions .r2v-stat strong {\n    font-size:17px;\n  }\n  #unima-r2v-dimensions .r2v-stat span {\n    font-size:10px;\n  }\n}\n<\/style>\n\n<div class=\"r2v-head\">\n  <div class=\"r2v-label\">\n    UNIMA CABLE | TECHNICAL DIMENSIONS\n  <\/div>\n  <h2>U-1000 R2V \u2013 Available Cable Dimensions<\/h2>\n  <p>\n    Nominal cross-sections, maximum conductor resistance\n    at 20\u00b0C, maximum outer diameter, copper weight\n    and approximate cable weight.\n  <\/p>\n<\/div>\n\n<div class=\"r2v-body\">\n\n  <div class=\"r2v-stats\">\n    <div class=\"r2v-stat\">\n      <strong>0.6\/1 kV<\/strong>\n      <span>Radni napon<\/span>\n    <\/div>\n    <div class=\"r2v-stat\">\n      <strong>Cu \/ XLPE<\/strong>\n      <span>Conductor \/ Insulation<\/span>\n    <\/div>\n    <div class=\"r2v-stat\">\n      <strong>77<\/strong>\n      <span>Cable Configurations<\/span>\n    <\/div>\n  <\/div>\n\n  <div class=\"r2v-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>Cable Size<br>(mm\u00b2)<\/th>\n          <th>Max. Resistance<br>at 20\u00b0C (\u03a9\/km)<\/th>\n          <th>Max. Outer<br>Diameter (mm)<\/th>\n          <th>Copper Weight<br>(kg\/km)<\/th>\n          <th>Approx. Cable<br>Weight (kg\/km)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody id=\"unima-r2v-table-body\"><\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"r2v-note\">\n    <strong>Technical Note:<\/strong>\n    Outer diameters are maximum values.\n    Cable weights are approximate.\n    Electrical characteristics and installation\n    conditions must be verified for the selected\n    cable configuration.\n  <\/div>\n\n<\/div>\n\n<script>\n(function() {\n  \"use strict\";\n\n  const raw = `\n1x4|4.61|6.8|38.4|81\n1x6|3.08|7.0|57.6|102\n1x10|1.830|7.8|96.0|148\n1x16|1.150|8.7|153.6|213\n1x25|0.727|10.2|240.0|316\n1x35|0.524|11.3|336.0|423\n1x50|0.387|12.8|480.0|583\n1x70|0.268|14.4|672.0|793\n1x95|0.193|16.2|912.0|1057\n1x120|0.153|17.8|1152.0|1317\n1x150|0.124|19.8|1440.0|1642\n1x185|0.0991|21.7|1776.0|2009\n1x240|0.0754|24.3|2304.0|2584\n1x300|0.0601|26.7|2880.0|3207\n1x400|0.0470|30.4|3840.0|4244\n1x500|0.0366|33.6|4800.0|5280\n1x630|0.0283|37.5|6048.0|6636\n1x800|0.0221|41.7|7680.0|8377\n2x1.5|12.1|11.0|28.8|151\n2x2.5|7.41|11.8|48.0|184\n2x4|4.61|13.0|76.8|241\n2x6|3.08|14.0|115.2|306\n2x10|1.830|16.0|192.0|434\n2x16|1.150|18.5|307.2|605\n2x25|0.727|22.0|480.0|889\n2x35|0.524|26.0|672.0|1168\n3x1.5|12.1|11.5|43.2|170\n3x2.5|7.41|12.3|72.0|211\n3x4|4.61|13.0|115.2|285\n3x6|3.08|15.0|172.8|369\n3x10|1.830|17.0|288.0|529\n3x16|1.150|19.5|460.8|755\n3x25|0.727|23.5|720.0|1122\n3x35|0.524|26.0|1008.0|1490\n3x50|0.387|29.5|1440.0|2049\n3x70|0.268|34.0|2016.0|2808\n3x95|0.193|38.5|2736.0|3704\n3x120|0.153|42.5|3456.0|4627\n3x150|0.124|47.5|4320.0|5770\n3x185|0.0991|53.0|5328.0|7080\n3x240|0.0754|59.5|6912.0|9080\n3x300|0.0601|66.0|8640.0|11233\n3x35+25|0.524|27.2|1196|1680\n3x50+35|0.387|31.1|1702|2225\n3x70+50|0.268|36.2|2392|3120\n3x95+50|0.193|40.6|3082|3910\n3x120+70|0.153|45.4|3956|5090\n3x150+70|0.124|49.5|4784|6055\n3x185+70|0.0991|54.4|5750|7400\n3x240+95|0.0754|61.5|7498|9590\n4x1.5|12.1|12.2|57.6|192\n4x2.5|7.41|13.1|96|241\n4x4|4.61|14.0|153.6|333\n4x6|3.08|16.0|230.4|436\n4x10|1.830|18.5|384|636\n4x16|1.150|21.0|614.4|921\n4x25|0.727|25.5|960|1380\n4x35|0.524|28.5|1344|1846\n4x50|0.387|32.5|1920|2560\n4x70|0.268|37.5|2688|3542\n4x95|0.193|42.5|3648|4679\n4x120|0.153|47.5|4608|5872\n4x150|0.124|52.5|5760|7301\n4x185|0.0991|59.0|7104|8988\n4x240|0.0754|66.5|9216|11538\n4x300|0.0601|73.5|11520|14288\n5x1.5|12.1|13.0|72|220\n5x2.5|7.41|14.0|120|231\n5x4|4.61|15.5|192|331\n5x6|3.08|17.5|288|444\n5x10|1.830|20.0|480|758\n5x16|1.150|23.0|768|1107\n5x25|0.727|27.0|1200|1665\n5x35|0.524|30.5|1680|2236\n5x50|0.387|34.0|2400|3116\n5x70|0.268|36.4|3360|4287\n5x95|0.193|40.6|4560|5661\n  `;\n\n  const tbody = document.querySelector(\n    \"#unima-r2v-table-body\"\n  );\n\n  if (!tbody) return;\n\n  raw.trim().split(\/\\r?\\n\/).forEach(function(line) {\n    const values = line.trim().split(\"|\");\n    if (values.length !== 5) return;\n\n    const tr = document.createElement(\"tr\");\n\n    values.forEach(function(value) {\n      const td = document.createElement(\"td\");\n      td.textContent = value.trim();\n      tr.appendChild(td);\n    });\n\n    tbody.appendChild(tr);\n  });\n})();\n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5134,"parent":0,"menu_order":0,"template":"","property_type":[47],"property_status":[],"property_feature":[],"property_label":[66,81,98],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-5133","property","type-property","status-publish","has-post-thumbnail","hentry","property_type-power-cables-1-30-kv","property_label-commercial-building","property_label-industrial-facilities","property_label-waterfront"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"U-1000 R2V - Unima cable\" \/>\n\t\t<meta property=\"og:description\" content=\"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-22T01:08:19+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T01:11:29+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"U-1000 R2V - Unima cable\" \/>\n\t\t<meta name=\"twitter:description\" content=\"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"name\":\"Power cables 1 - 30 kV\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"position\":3,\"name\":\"Power cables 1 - 30 kV\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#listItem\",\"name\":\"U-1000 R2V\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#listItem\",\"position\":4,\"name\":\"U-1000 R2V\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"name\":\"Power cables 1 - 30 kV\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/\",\"name\":\"U-1000 R2V - Unima cable\",\"description\":\"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\\\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Untitled-Design-42.png\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#mainImage\",\"width\":500,\"height\":500},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/u-1000-r2v\\\/#mainImage\"},\"datePublished\":\"2026-10-22T01:08:19+00:00\",\"dateModified\":\"2026-10-22T01:11:29+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"U-1000 R2V - Unima cable","description":"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","name":"Power cables 1 - 30 kV"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","position":3,"name":"Power cables 1 - 30 kV","item":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#listItem","name":"U-1000 R2V"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#listItem","position":4,"name":"U-1000 R2V","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","name":"Power cables 1 - 30 kV"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/","name":"U-1000 R2V - Unima cable","description":"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/unima-cable.com\/wp-content\/uploads\/2026\/10\/Untitled-Design-42.png","@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#mainImage","width":500,"height":500},"primaryImageOfPage":{"@id":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/#mainImage"},"datePublished":"2026-10-22T01:08:19+00:00","dateModified":"2026-10-22T01:11:29+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"U-1000 R2V - Unima cable","og:description":"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at","og:url":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/","article:published_time":"2026-10-22T01:08:19+00:00","article:modified_time":"2026-10-22T01:11:29+00:00","twitter:card":"summary_large_image","twitter:title":"U-1000 R2V - Unima cable","twitter:description":"UNIMA CABLE | POWER CABLES U-1000 R2V Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6\/1 kV U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at"},"aioseo_meta_data":{"post_id":"5133","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-10-22 01:08:20","updated":"2026-10-22 01:11:29"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/\" title=\"Power cables 1 - 30 kV\">Power cables 1 - 30 kV<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tU-1000 R2V\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Power cables 1 - 30 kV","link":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/"},{"label":"U-1000 R2V","link":"https:\/\/unima-cable.com\/hr\/property\/u-1000-r2v\/"}],"property_meta":{"_edit_lock":["1792631983:1"],"_thumbnail_id":["5134"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_cable-type":["U-1000 R2V"],"fave_application":["Low Voltage Power Distribution"],"fave_conductor-material":["Copper, Class 1 or Class 2"],"fave_insulation-material":["XLPE"],"fave_rated-voltage":["0.6\/1 kV"],"fave_cpr-class":["Eca"],"fave_standard":["NF C 32-321 \/ IEC 60502-1"],"fave_packaging":["Wooden Drums \/ On Request"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"additional_features":["a:5:{i:0;a:2:{s:29:\"fave_additional_feature_title\";s:12:\"Test Voltage\";s:29:\"fave_additional_feature_value\";s:4:\"4 kV\";}i:1;a:2:{s:29:\"fave_additional_feature_title\";s:29:\"Maximum Operating Temperature\";s:29:\"fave_additional_feature_value\";s:6:\"+90\u00b0C\";}i:2;a:2:{s:29:\"fave_additional_feature_title\";s:33:\"Maximum Short-Circuit Temperature\";s:29:\"fave_additional_feature_value\";s:7:\"+250\u00b0C\";}i:3;a:2:{s:29:\"fave_additional_feature_title\";s:12:\"Outer Sheath\";s:29:\"fave_additional_feature_value\";s:10:\"PVC, Black\";}i:4;a:2:{s:29:\"fave_additional_feature_title\";s:19:\"Core Identification\";s:29:\"fave_additional_feature_value\";s:9:\"HD 308 S2\";}}"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":["\r\n1x4|81|38.4\r\n1x6|102|57.6\r\n1x10|148|96\r\n1x16|213|153.6\r\n1x25|316|240\r\n1x35|423|336\r\n1x50|583|480\r\n1x70|793|672\r\n1x95|1057|912\r\n1x120|1317|1152\r\n1x150|1642|1440\r\n1x185|2009|1776\r\n1x240|2584|2304\r\n1x300|3207|2880\r\n1x400|4244|3840\r\n1x500|5280|4800\r\n1x630|6636|6048\r\n1x800|8377|7680\r\n2x1.5|151|28.8\r\n2x2.5|184|48\r\n2x4|241|76.8\r\n2x6|306|115.2\r\n2x10|434|192\r\n2x16|605|307.2\r\n2x25|889|480\r\n2x35|1168|672\r\n3x1.5|170|43.2\r\n3x2.5|211|72\r\n3x4|285|115.2\r\n3x6|369|172.8\r\n3x10|529|288\r\n3x16|755|460.8\r\n3x25|1122|720\r\n3x35|1490|1008\r\n3x50|2049|1440\r\n3x70|2808|2016\r\n3x95|3704|2736\r\n3x120|4627|3456\r\n3x150|5770|4320\r\n3x185|7080|5328\r\n3x240|9080|6912\r\n3x300|11233|8640\r\n3x35+25|1680|1196\r\n3x50+35|2225|1702\r\n3x70+50|3120|2392\r\n3x95+50|3910|3082\r\n3x120+70|5090|3956\r\n3x150+70|6055|4784\r\n3x185+70|7400|5750\r\n3x240+95|9590|7498\r\n4x1.5|192|57.6\r\n4x2.5|241|96\r\n4x4|333|153.6\r\n4x6|436|230.4\r\n4x10|636|384\r\n4x16|921|614.4\r\n4x25|1380|960\r\n4x35|1846|1344\r\n4x50|2560|1920\r\n4x70|3542|2688\r\n4x95|4679|3648\r\n4x120|5872|4608\r\n4x150|7301|5760\r\n4x185|8988|7104\r\n4x240|11538|9216\r\n4x300|14288|11520\r\n5x1.5|220|72\r\n5x2.5|231|120\r\n5x4|331|192\r\n5x6|444|288\r\n5x10|758|480\r\n5x16|1107|768\r\n5x25|1665|1200\r\n5x35|2236|1680\r\n5x50|3116|2400\r\n5x70|4287|3360\r\n5x95|5661|4560\r\n"],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":[" U-1000 R2V | Low Voltage Power Cable | 0.6\/1 kV | Copper \/ XLPE \/ PVC | CPR Eca"],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":["U-1000 R2V is a 0.6\/1 kV low-voltage power cable with Class 1 or Class 2 copper conductors, XLPE insulation and a black PVC outer sheath. Designed for fixed installations in buildings, industrial facilities and power distribution networks, including outdoor and mechanically protected underground installations. Maximum operating temperature: 90\u00b0C. Standards: NF C32-321 \/ IEC 60502-1. CPR class: Eca.\r\n"],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":["\r\nConductor|Copper, Class 1 Solid \/ Class 2 Stranded\r\nConductor Standard|EN 60228\r\nInsulation|XLPE Compound\r\nBedding|Extruded Compound or Plastic Tape\r\nOuter Sheath|PVC Compound\r\nSheath Colour|Black\r\nCore Identification|HD 308 S2\r\n"],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":["NF C 32-321\r\nIEC 60502-1\r\nEN 60228\r\nHD 308 S2\r\nEN 50575\r\n"],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":["\r\nLow Voltage Power Distribution\r\nIndustrial Electrical Installations\r\nResidential and Commercial Buildings\r\nUrban Distribution Networks\r\nOutdoor Fixed Installations\r\nCable Trays and Conduits\r\nProtected Underground Installations\r\n"],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":["Rated Voltage|0.6\/1 kV\r\nTest Voltage|4 kV\r\nOperating Temperature|+90\u00b0C\r\nShort-Circuit Temperature|+250\u00b0C\r\nMinimum Laying Temperature|-5\u00b0C\r\nBending Radius|12 \u00d7 D (multi-core) \/ 15 \u00d7 D (single-core)\r\nConductor Class|Class 1 \/ Class 2\r\nCPR Classification|Eca\r\n\r\nOuter Sheath|PVC, Black\r\nCore Identification|HD 308 S2\r\nCPR Classification|Eca\r\n"],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":["\r\nsize|resistance20|outer_diameter|copper_weight|cable_weight\r\n1x4|4.61|6.8|38.4|81\r\n1x6|3.08|7.0|57.6|102\r\n1x10|1.830|7.8|96.0|148\r\n1x16|1.150|8.7|153.6|213\r\n1x25|0.727|10.2|240.0|316\r\n1x35|0.524|11.3|336.0|423\r\n1x50|0.387|12.8|480.0|583\r\n1x70|0.268|14.4|672.0|793\r\n1x95|0.193|16.2|912.0|1057\r\n1x120|0.153|17.8|1152.0|1317\r\n1x150|0.124|19.8|1440.0|1642\r\n1x185|0.0991|21.7|1776.0|2009\r\n1x240|0.0754|24.3|2304.0|2584\r\n1x300|0.0601|26.7|2880.0|3207\r\n1x400|0.0470|30.4|3840.0|4244\r\n1x500|0.0366|33.6|4800.0|5280\r\n1x630|0.0283|37.5|6048.0|6636\r\n1x800|0.0221|41.7|7680.0|8377\r\n2x1.5|12.1|11.0|28.8|151\r\n2x2.5|7.41|11.8|48.0|184\r\n2x4|4.61|13.0|76.8|241\r\n2x6|3.08|14.0|115.2|306\r\n2x10|1.830|16.0|192.0|434\r\n2x16|1.150|18.5|307.2|605\r\n2x25|0.727|22.0|480.0|889\r\n2x35|0.524|26.0|672.0|1168\r\n3x1.5|12.1|11.5|43.2|170\r\n3x2.5|7.41|12.3|72.0|211\r\n3x4|4.61|13.0|115.2|285\r\n3x6|3.08|15.0|172.8|369\r\n3x10|1.830|17.0|288.0|529\r\n3x16|1.150|19.5|460.8|755\r\n3x25|0.727|23.5|720.0|1122\r\n3x35|0.524|26.0|1008.0|1490\r\n3x50|0.387|29.5|1440.0|2049\r\n3x70|0.268|34.0|2016.0|2808\r\n3x95|0.193|38.5|2736.0|3704\r\n3x120|0.153|42.5|3456.0|4627\r\n3x150|0.124|47.5|4320.0|5770\r\n3x185|0.0991|53.0|5328.0|7080\r\n3x240|0.0754|59.5|6912.0|9080\r\n3x300|0.0601|66.0|8640.0|11233\r\n3x35+25|0.524|27.2|1196|1680\r\n3x50+35|0.387|31.1|1702|2225\r\n3x70+50|0.268|36.2|2392|3120\r\n3x95+50|0.193|40.6|3082|3910\r\n3x120+70|0.153|45.4|3956|5090\r\n3x150+70|0.124|49.5|4784|6055\r\n3x185+70|0.0991|54.4|5750|7400\r\n3x240+95|0.0754|61.5|7498|9590\r\n4x1.5|12.1|12.2|57.6|192\r\n4x2.5|7.41|13.1|96|241\r\n4x4|4.61|14.0|153.6|333\r\n4x6|3.08|16.0|230.4|436\r\n4x10|1.830|18.5|384|636\r\n4x16|1.150|21.0|614.4|921\r\n4x25|0.727|25.5|960|1380\r\n4x35|0.524|28.5|1344|1846\r\n4x50|0.387|32.5|1920|2560\r\n4x70|0.268|37.5|2688|3542\r\n4x95|0.193|42.5|3648|4679\r\n4x120|0.153|47.5|4608|5872\r\n4x150|0.124|52.5|5760|7301\r\n4x185|0.0991|59.0|7104|8988\r\n4x240|0.0754|66.5|9216|11538\r\n4x300|0.0601|73.5|11520|14288\r\n5x1.5|12.1|13.0|72|220\r\n5x2.5|7.41|14.0|120|231\r\n5x4|4.61|15.5|192|331\r\n5x6|3.08|17.5|288|444\r\n5x10|1.830|20.0|480|758\r\n5x16|1.150|23.0|768|1107\r\n5x25|0.727|27.0|1200|1665\r\n5x35|0.524|30.5|1680|2236\r\n5x50|0.387|34.0|2400|3116\r\n5x70|0.268|36.4|3360|4287\r\n5x95|0.193|40.6|4560|5661\r\n"],"_datasheet_size_data":["field_6ab787279d659"],"datasheet_highlights":["Rated Voltage|0.6\/1 kV\r\nInsulation|XLPE\r\nOperating Temperature|90\u00b0C\r\nCPR Class|Eca\r\n"],"_datasheet_highlights":["field_6ad9232e89762"],"datasheet_category":["LOW VOLTAGE POWER CABLES"],"_datasheet_category":["field_6ad929e8ec019"],"datasheet_technical_notes":["Dimensions and weights are nominal or approximate values. Current-carrying capacities depend on installation conditions. Underground installation requires appropriate mechanical protection. Technical specifications are subject to confirmation for the selected cable configuration.\r\n"],"_datasheet_technical_notes":["field_6ad92a005051a"],"datasheet_cpr_class":[" Eca"],"_datasheet_cpr_class":["field_6ad92a1bdd6aa"],"_aioseo_title":[null],"_aioseo_description":[null],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["8"],"houzez_views_by_date":["a:1:{s:10:\"10-22-2026\";i:8;}"],"houzez_recently_viewed":["2026-10-22 05:40:20"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5133\/revisions"}],"predecessor-version":[{"id":5135,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5133\/revisions\/5135"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media\/5134"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=5133"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=5133"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=5133"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=5133"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=5133"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=5133"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=5133"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=5133"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=5133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}