{"id":4824,"date":"2026-10-13T00:23:35","date_gmt":"2026-10-13T00:23:35","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=4824"},"modified":"2026-10-13T01:08:27","modified_gmt":"2026-10-13T01:08:27","slug":"n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/","title":{"rendered":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV"},"content":{"rendered":"\n<div id=\"unima-n2xy-overview\">\n<style>\n#unima-n2xy-overview{\n  --navy:#071a2d;--blue:#0878c9;--line:#dce7ef;\n  font-family:Arial,Helvetica,sans-serif;\n  color:var(--navy);line-height:1.65;margin:25px 0\n}\n#unima-n2xy-overview *{box-sizing:border-box}\n#unima-n2xy-overview .hero{\n  background:linear-gradient(130deg,#071a2d,#123c60);\n  color:#fff;border-radius:14px;padding:32px\n}\n#unima-n2xy-overview .eyebrow{\n  font-size:11px;font-weight:800;letter-spacing:2px;\n  color:#72c9ff;margin-bottom:10px\n}\n#unima-n2xy-overview .hero h2{\n  color:white;font-size:28px;line-height:1.3;\n  margin:0 0 12px\n}\n#unima-n2xy-overview .hero p{\n  color:#d5e7f5;font-size:14px;margin:0\n}\n#unima-n2xy-overview .tags{\n  display:flex;gap:8px;flex-wrap:wrap;margin-top:20px\n}\n#unima-n2xy-overview .tags span{\n  background:rgba(255,255,255,.09);\n  border:1px solid rgba(255,255,255,.23);\n  border-radius:30px;padding:7px 12px;\n  color:white;font-size:11px;font-weight:700\n}\n#unima-n2xy-overview .section{margin-top:27px}\n#unima-n2xy-overview h3{\n  border-left:5px solid var(--blue);\n  padding-left:12px;font-size:21px;margin:0 0 16px\n}\n#unima-n2xy-overview .intro{\n  border:1px solid var(--line);\n  border-radius:10px;padding:22px;\n  color:#35495c;font-size:14px\n}\n#unima-n2xy-overview .intro p{\n  margin:0 0 12px\n}\n#unima-n2xy-overview .intro p:last-child{margin:0}\n#unima-n2xy-overview .features{\n  display:grid;grid-template-columns:repeat(4,1fr);\n  gap:11px\n}\n#unima-n2xy-overview .feature{\n  background:#f3f8fc;border:1px solid var(--line);\n  border-radius:10px;padding:20px 12px;text-align:center\n}\n#unima-n2xy-overview .feature strong{\n  display:block;font-size:19px;margin-bottom:5px\n}\n#unima-n2xy-overview .feature small{\n  display:block;color:#5b6d7d;font-size:11px\n}\n#unima-n2xy-overview .panels{\n  display:grid;grid-template-columns:1fr 1fr;gap:16px\n}\n#unima-n2xy-overview .panel{\n  border:1px solid var(--line);\n  border-radius:10px;overflow:hidden\n}\n#unima-n2xy-overview .panel h4{\n  background:#102d48;color:#fff;\n  padding:15px;margin:0;font-size:15px\n}\n#unima-n2xy-overview .item{\n  display:grid;grid-template-columns:43% 57%;\n  gap:8px;padding:12px 15px;\n  border-bottom:1px solid var(--line);\n  font-size:12px\n}\n#unima-n2xy-overview .item span{color:#607487}\n#unima-n2xy-overview .item b{color:#071a2d}\n#unima-n2xy-overview .applications{\n  display:grid;grid-template-columns:1fr 1fr;gap:10px\n}\n#unima-n2xy-overview .app{\n  background:#f3f8fc;border:1px solid var(--line);\n  border-radius:8px;padding:14px;font-size:13px\n}\n#unima-n2xy-overview .app:before{\n  content:\"\u2713\";color:var(--blue);\n  font-weight:900;margin-right:10px\n}\n#unima-n2xy-overview .note{\n  background:#f5f9fc;border-left:4px solid var(--blue);\n  padding:18px;margin-top:24px;\n  color:#43586b;font-size:12px\n}\n@media(max-width:700px){\n  #unima-n2xy-overview .features{\n    grid-template-columns:repeat(2,1fr)\n  }\n  #unima-n2xy-overview .panels,\n  #unima-n2xy-overview .applications{\n    grid-template-columns:1fr\n  }\n  #unima-n2xy-overview .hero{padding:24px}\n  #unima-n2xy-overview .hero h2{font-size:22px}\n}\n<\/style>\n\n<div class=\"hero\">\n  <div class=\"eyebrow\">\n    UNIMA CABLE | LOW VOLTAGE POWER SOLUTIONS\n  <\/div>\n  <h2>\n    N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable\n  <\/h2>\n  <p>\n    Copper power cable with cross-linked polyethylene\n    insulation and a PVC outer sheath. Designed for\n    fixed installation in buildings, industrial\n    facilities, underground routes and outdoor\n    power distribution networks.\n  <\/p>\n  <div class=\"tags\">\n    <span>0.6\/1 kV<\/span>\n    <span>XLPE Insulation<\/span>\n    <span>Class 2 Copper<\/span>\n    <span>CPR Eca<\/span>\n    <span>UV Resistant<\/span>\n    <span>VDE 0276-603<\/span>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Product Overview<\/h3>\n  <div class=\"intro\">\n    <p>\n      <strong>N2XY<\/strong> is a low-voltage power\n      cable with bare copper conductors, XLPE\n      insulation and a PVC outer sheath.\n      It is suitable for fixed installation indoors,\n      outdoors, in the ground and in water.\n    <\/p>\n    <p>\n      The cable is available in <strong>N2XY-J<\/strong>\n      versions with a protective conductor and\n      <strong>N2XY-O<\/strong> versions without\n      a protective conductor.\n    <\/p>\n    <p>\n      XLPE insulation supports a maximum conductor\n      operating temperature of 90\u00b0C and a short-circuit\n      conductor temperature of up to 250\u00b0C.\n      The cable is flame-retardant according to\n      IEC 60332-1-2 and UV-resistant.\n    <\/p>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Key Technical Features<\/h3>\n  <div class=\"features\">\n    <div class=\"feature\">\n      <strong>0.6\/1 kV<\/strong>\n      <small>Rated Voltage<\/small>\n    <\/div>\n    <div class=\"feature\">\n      <strong>90\u00b0C<\/strong>\n      <small>Maximum Conductor Temperature<\/small>\n    <\/div>\n    <div class=\"feature\">\n      <strong>Eca<\/strong>\n      <small>CPR Classification<\/small>\n    <\/div>\n    <div class=\"feature\">\n      <strong>4 kV<\/strong>\n      <small>Test Voltage<\/small>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Construction &amp; Technical Properties<\/h3>\n  <div class=\"panels\">\n    <div class=\"panel\">\n      <h4>Cable Construction<\/h4>\n      <div class=\"item\"><span>Conductor<\/span><b>Bare Copper<\/b><\/div>\n      <div class=\"item\"><span>Conductor Class<\/span><b>Class 2 Stranded<\/b><\/div>\n      <div class=\"item\"><span>Core Insulation<\/span><b>XLPE<\/b><\/div>\n      <div class=\"item\"><span>Outer Sheath<\/span><b>PVC<\/b><\/div>\n      <div class=\"item\"><span>Core Identification<\/span><b>VDE 0293 \/ HD 308<\/b><\/div>\n      <div class=\"item\"><span>N2XY-J<\/span><b>With Protective Conductor<\/b><\/div>\n      <div class=\"item\"><span>N2XY-O<\/span><b>Without Protective Conductor<\/b><\/div>\n    <\/div>\n    <div class=\"panel\">\n      <h4>Electrical &amp; Mechanical Data<\/h4>\n      <div class=\"item\"><span>Rated Voltage<\/span><b>0.6\/1 kV<\/b><\/div>\n      <div class=\"item\"><span>Maximum System Voltage<\/span><b>1.2 kV<\/b><\/div>\n      <div class=\"item\"><span>Test Voltage<\/span><b>4 kV<\/b><\/div>\n      <div class=\"item\"><span>Conductor Temperature<\/span><b>Max. 90\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Short Circuit Temperature<\/span><b>Max. 250\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Outer Cable, Fixed<\/span><b>Max. +50\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Outer Cable, Moved<\/span><b>-5\u00b0C to +50\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Bending Radius, Multicore<\/span><b>12 \u00d7 \u00d8<\/b><\/div>\n      <div class=\"item\"><span>Bending Radius, Single-Core<\/span><b>15 \u00d7 \u00d8<\/b><\/div>\n      <div class=\"item\"><span>UV Resistance<\/span><b>Yes<\/b><\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Typical Applications<\/h3>\n  <div class=\"applications\">\n    <div class=\"app\">Low Voltage Power Distribution<\/div>\n    <div class=\"app\">Industrial Facilities<\/div>\n    <div class=\"app\">Commercial Buildings<\/div>\n    <div class=\"app\">Underground Power Cable Routes<\/div>\n    <div class=\"app\">Outdoor Electrical Installations<\/div>\n    <div class=\"app\">Fixed Installation in Water<\/div>\n    <div class=\"app\">Electrical Infrastructure<\/div>\n    <div class=\"app\">Building Power Supply Systems<\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Applicable Standards<\/h3>\n  <div class=\"intro\">\n    <strong>VDE 0276-603<\/strong> \u2013 Cable construction\n    and technical requirements.<br>\n    <strong>EN 50575<\/strong> \u2013 CPR classification Eca.<br>\n    <strong>IEC 60332-1-2<\/strong> \u2013 Flame retardance.<br>\n    <strong>VDE 0293 \/ HD 308<\/strong> \u2013 Core identification.\n  <\/div>\n<\/div>\n\n<div class=\"note\">\n  <strong>Technical Notice:<\/strong>\n  Current-carrying capacities depend on the\n  installation method and ambient conditions.\n  Cable diameters and weights are approximate.\n  Product availability and packaging are\n  subject to confirmation.\n<\/div>\n<\/div>\n\n\n\n<div id=\"unima-n2xy-range\">\n<style>\n#unima-n2xy-range{\n --navy:#071a2d;--blue:#0878c9;--line:#dce7ef;\n font-family:Arial,Helvetica,sans-serif;color:var(--navy);\n margin:25px 0\n}\n#unima-n2xy-range *{box-sizing:border-box}\n#unima-n2xy-range .head{\n background:var(--navy);color:#fff;\n padding:25px;border-radius:12px 12px 0 0\n}\n#unima-n2xy-range .head h2{\n color:white;font-size:24px;margin:0 0 8px\n}\n#unima-n2xy-range .head p{\n color:#c3d7e7;font-size:13px;margin:0\n}\n#unima-n2xy-range .body{\n padding:20px;border:1px solid var(--line);\n border-radius:0 0 12px 12px\n}\n#unima-n2xy-range .stats{\n display:grid;grid-template-columns:repeat(4,1fr);\n gap:10px;margin-bottom:20px\n}\n#unima-n2xy-range .stat{\n background:#f3f8fc;border:1px solid var(--line);\n border-radius:8px;padding:15px 8px;text-align:center\n}\n#unima-n2xy-range .stat b{\n display:block;font-size:18px\n}\n#unima-n2xy-range .stat small{\n color:#607487;font-size:11px\n}\n#unima-n2xy-range .filters{\n display:flex;gap:10px;flex-wrap:wrap;margin-bottom:16px\n}\n#unima-n2xy-range input,\n#unima-n2xy-range select{\n flex:1;min-width:170px;padding:12px;\n border:1px solid #cbdde9;border-radius:8px;\n background:white;color:#071a2d;font-size:13px\n}\n#unima-n2xy-range .scroll{\n overflow-x:auto;border:1px solid var(--line);\n border-radius:9px\n}\n#unima-n2xy-range table{\n width:100%;min-width:1050px;border-collapse:collapse;\n margin:0;font-size:12px\n}\n#unima-n2xy-range th{\n background:#102d48;color:white;\n padding:13px 9px;text-align:center\n}\n#unima-n2xy-range td{\n padding:11px 9px;text-align:center;\n border-bottom:1px solid #e5edf3;white-space:nowrap\n}\n#unima-n2xy-range tbody tr:nth-child(even){\n background:#f5f9fc\n}\n#unima-n2xy-range tbody tr:hover{\n background:#eaf5fd\n}\n#unima-n2xy-range td:nth-child(2){\n font-weight:800;color:#075c9c\n}\n#unima-n2xy-range .foot{\n margin-top:13px;color:#607487;font-size:12px\n}\n#unima-n2xy-range .note{\n background:#f5f9fc;border-left:4px solid var(--blue);\n margin-top:20px;padding:17px;\n font-size:12px;line-height:1.7;color:#43586b\n}\n@media(max-width:650px){\n #unima-n2xy-range .stats{\n  grid-template-columns:repeat(2,1fr)\n }\n}\n<\/style>\n\n<div class=\"head\">\n <h2>Technical Data &amp; Cable Dimensions<\/h2>\n <p>N2XY-J \/ N2XY-O | 0.6\/1 kV | VDE 0276-603<\/p>\n<\/div>\n\n<div class=\"body\">\n <div class=\"stats\">\n  <div class=\"stat\"><b>37<\/b><small>Configurations<\/small><\/div>\n  <div class=\"stat\"><b>0.6\/1 kV<\/b><small>Rated Voltage<\/small><\/div>\n  <div class=\"stat\"><b>90\u00b0C<\/b><small>Max. Conductor Temp.<\/small><\/div>\n  <div class=\"stat\"><b>Eca<\/b><small>CPR Classification<\/small><\/div>\n <\/div>\n\n <div class=\"filters\">\n  <select class=\"type\" aria-label=\"Cable variant\">\n   <option value=\"\">All Cable Variants<\/option>\n   <option value=\"N2XY-J\">N2XY-J<\/option>\n   <option value=\"N2XY-O\">N2XY-O<\/option>\n  <\/select>\n  <input class=\"search\" type=\"search\"\n   placeholder=\"Search e.g. 4x50 or 5x2.5\"\n   aria-label=\"Search cable size\">\n <\/div>\n\n <div class=\"scroll\">\n  <table>\n   <thead>\n    <tr>\n     <th>Type<\/th>\n     <th>Size<\/th>\n     <th>Conductor<\/th>\n     <th>Resistance<br>\u03a9\/km<\/th>\n     <th>Air<br>A<\/th>\n     <th>Ground<br>A<\/th>\n     <th>Outer \u00d8<br>mm<\/th>\n     <th>Copper<br>kg\/km<\/th>\n     <th>Cable<br>kg\/km<\/th>\n    <\/tr>\n   <\/thead>\n   <tbody class=\"data\"><\/tbody>\n  <\/table>\n <\/div>\n\n <div class=\"foot\">\n  <span class=\"count\"><\/span>\n  | Source: Klaus Faber AG, N2XY VDE\n <\/div>\n\n <div class=\"note\">\n  <strong>Technical notes:<\/strong>\n  Air ampacity at 30\u00b0C ambient temperature.\n  Ground ampacity at 20\u00b0C ground temperature.\n  A dash indicates that the manufacturer\n  has not supplied an ampacity value.\n  <br><br>\n  RE = round solid conductor;\n  RM = round stranded conductor;\n  SM = sector-shaped stranded conductor.\n  The suffix &#8220;v&#8221; is retained from the\n  manufacturer&#8217;s conductor designation.\n  <br><br>\n  All diameters and weights are approximate.\n  Current ratings must be corrected for actual\n  installation conditions.\n  The separate UNIMA weight calculator is not\n  included in this HTML block.\n <\/div>\n<\/div>\n\n<script>\n(function(){\n const root=document.getElementById(\"unima-n2xy-range\");\n if(!root||root.dataset.initialized===\"1\")return;\n root.dataset.initialized=\"1\";\n\n \/\/ type|size|conductor|resistance|air|ground|diameter|copper|weight\n const raw=`\nN2XY-O|1x50|RMv|0.387|207|209|14.7|480|565\nN2XY-O|1x70|RMv|0.268|263|256|16.6|672|775\nN2XY-O|1x95|RMv|0.193|325|307|17.9|912|980\nN2XY-O|1x120|RMv|0.153|380|349|19.4|1152|1248\nN2XY-O|1x150|RMv|0.124|437|393|21.7|1440|1538\nN2XY-O|1x185|RMv|0.0991|507|445|23.3|1776|1882\nN2XY-O|1x240|RMv|0.0754|604|517|26|2304|2415\nN2XY-O|1x300|RMv|0.0601|697|583|29|2880|3000\nN2XY-O|1x400|RMv|0.047|811|663|31.5|3840|4100\nN2XY-O|1x500|RMv|0.0366|940|749|38|4800|4942\nN2XY-J|1x150|RMv|0.124|||21.5|1440|1500\nN2XY-J|1x120|RMv|0.153|||19.4|1152|1248\nN2XY-J|1x185|RMv|0.0991|||23.3|1776|1882\nN2XY-J|1x240|RMv|0.0754|||26|2304|2415\nN2XY-J|3x1.5|RE|12.1|24|31|11.4|43.2|190\nN2XY-J|3x2.5|RE|7.41|32|40|12.2|72|232\nN2XY-J|3x16|RMv|1.15|98|112|18.5|461|817\nN2XY-J|4x4|RE|4.61|42|52|14.2|154|350\nN2XY-J|4x6|RE|3.08|53|64|15.6|230|460\nN2XY-J|4x10|RE|1.83|86|74|17.4|384|640\nN2XY-J|4x16|RM|1.15|98|112|21.9|614|1150\nN2XY-J|4x25|RMv|0.727|133|145|24.8|960|1420\nN2XY-J|4x35|RMv|0.524|162|174|27.2|1344|1830\nN2XY-J|4x50|SMv|0.387|197|206|28.1|1920|2040\nN2XY-J|4x70|SMv|0.268|250|254|32.5|2688|2860\nN2XY-J|4x95|SMv|0.193|308|305|39|3648|4250\nN2XY-J|4x120|SMv|0.153|359|348|42.5|4608|5300\nN2XY-J|5x1.5|RE|12.1|24|31|13|72|246\nN2XY-J|5x2.5|RE|7.41|32|40|14|120|309\nN2XY-J|5x4|RE|4.61|42|52|17|192|394\nN2XY-J|5x6|RE|3.08|53|64|19|288|536\nN2XY-J|5x25|RM|0.727|133|145|29|1200|1735\nN2XY-J|8x1.5|RE|12.1|24|31|13.9|115|305\nN2XY-J|8x2.5|RE|7.41|32|40|15.1|192|399\nN2XY-J|12x1.5|RE|12.1|24|31|16.5|173|412\nN2XY-J|12x2.5|RE|7.41|32|40|18|288|549\nN2XY-J|14x1.5|RE|12.1|24|31|17.2|202|456\n`;\n\n const data=raw.trim().split(\"\\n\").map(line=>{\n  const v=line.split(\"|\");\n  return {\n   type:v[0],size:v[1],conductor:v[2],\n   resistance:v[3],air:v[4],ground:v[5],\n   diameter:v[6],copper:v[7],weight:v[8]\n  };\n });\n\n const tbody=root.querySelector(\".data\");\n const type=root.querySelector(\".type\");\n const search=root.querySelector(\".search\");\n const count=root.querySelector(\".count\");\n\n function render(){\n  const q=search.value.toLowerCase()\n   .replace(\/\\s+\/g,\"\").replace(\/\u00d7\/g,\"x\");\n\n  const rows=data.filter(x=>\n   (!type.value||x.type===type.value)&&\n   (x.type+\" \"+x.size+\" \"+x.conductor)\n    .toLowerCase().replace(\/\\s+\/g,\"\").includes(q)\n  );\n\n  tbody.replaceChildren();\n  rows.forEach(x=>{\n   const tr=document.createElement(\"tr\");\n   [\n    x.type,x.size,x.conductor,x.resistance,\n    x.air||\"\u2014\",x.ground||\"\u2014\",x.diameter,\n    x.copper,x.weight\n   ].forEach(value=>{\n    const td=document.createElement(\"td\");\n    td.textContent=value;\n    tr.appendChild(td);\n   });\n   tbody.appendChild(tr);\n  });\n\n  if(!rows.length){\n   const tr=document.createElement(\"tr\");\n   const td=document.createElement(\"td\");\n   td.colSpan=9;\n   td.textContent=\"No matching configurations\";\n   tr.appendChild(td);tbody.appendChild(tr);\n  }\n\n  count.textContent=\"Showing \"+rows.length+\n   \" of \"+data.length+\" configurations\";\n }\n\n type.addEventListener(\"change\",render);\n search.addEventListener(\"input\",render);\n render();\n})();\n<\/script>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | LOW VOLTAGE POWER SOLUTIONS N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable Copper power cable with cross-linked polyethylene insulation and a PVC outer sheath. Designed for fixed installation in buildings, industrial facilities, underground routes and outdoor power distribution networks. 0.6\/1 kV XLPE Insulation Class 2 Copper CPR Eca UV Resistant VDE 0276-603 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4825,"parent":0,"menu_order":0,"template":"","property_type":[203,47],"property_status":[],"property_feature":[],"property_label":[75,196,62,74],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-4824","property","type-property","status-publish","has-post-thumbnail","hentry","property_type-ev-charging-cables","property_type-power-cables-1-30-kv","property_label-batery-storage","property_label-data-center","property_label-solar-energy","property_label-wind-energy"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV - Unima cable\" \/>\n\t\t<meta property=\"og:description\" content=\"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-13T00:23:35+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-13T01:08:27+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV - Unima cable\" \/>\n\t\t<meta name=\"twitter:description\" content=\"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"name\":\"Power cables 1 - 30 kV\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"position\":3,\"name\":\"Power cables 1 - 30 kV\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#listItem\",\"name\":\"N2XY-J \\\/ N2XY-O \\u2013 Copper XLPE Power Cable 0.6\\\/1 kV\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#listItem\",\"position\":4,\"name\":\"N2XY-J \\\/ N2XY-O \\u2013 Copper XLPE Power Cable 0.6\\\/1 kV\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"name\":\"Power cables 1 - 30 kV\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/\",\"name\":\"N2XY-J \\\/ N2XY-O \\u2013 Copper XLPE Power Cable 0.6\\\/1 kV - Unima cable\",\"description\":\"N2XY Cable 0.6\\\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Untitled-design-54.png\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#mainImage\",\"width\":500,\"height\":500},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\\\/#mainImage\"},\"datePublished\":\"2026-10-13T00:23:35+00:00\",\"dateModified\":\"2026-10-13T01:08:27+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV - Unima cable","description":"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","name":"Power cables 1 - 30 kV"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","position":3,"name":"Power cables 1 - 30 kV","item":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#listItem","name":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#listItem","position":4,"name":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","name":"Power cables 1 - 30 kV"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/","name":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV - Unima cable","description":"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/unima-cable.com\/wp-content\/uploads\/2026\/10\/Untitled-design-54.png","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#mainImage","width":500,"height":500},"primaryImageOfPage":{"@id":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/#mainImage"},"datePublished":"2026-10-13T00:23:35+00:00","dateModified":"2026-10-13T01:08:27+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV - Unima cable","og:description":"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.","og:url":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/","article:published_time":"2026-10-13T00:23:35+00:00","article:modified_time":"2026-10-13T01:08:27+00:00","twitter:card":"summary_large_image","twitter:title":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV - Unima cable","twitter:description":"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE."},"aioseo_meta_data":{"post_id":"4824","title":null,"description":"N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-10-13 00:23:36","updated":"2026-10-13 01:09:16"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/\" title=\"Power cables 1 - 30 kV\">Power cables 1 - 30 kV<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tN2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Power cables 1 - 30 kV","link":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/"},{"label":"N2XY-J \/ N2XY-O \u2013 Copper XLPE Power Cable 0.6\/1 kV","link":"https:\/\/unima-cable.com\/hr\/property\/n2xy-j-n2xy-o-copper-xlpe-power-cable-0-6-1-kv\/"}],"property_meta":{"_edit_lock":["1791853708:1"],"_thumbnail_id":["4825"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_cable-type":["N2XY-J \/ N2XY-O"],"fave_application":["Power Distribution, Buildings & Industrial Installations"],"fave_conductor-material":["Bare Copper, Class 2 Stranded"],"fave_insulation-material":["XLPE"],"fave_rated-voltage":["0.6\/1 kV"],"fave_cpr-class":["Eca"],"fave_standard":["VDE 0276-603"],"fave_packaging":["Coils \/ Wooden Drums \u2013 On Request"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"additional_features":["a:3:{i:0;a:2:{s:29:\"fave_additional_feature_title\";s:14:\"Cable Function\";s:29:\"fave_additional_feature_value\";s:30:\"Low Voltage Power Distribution\";}i:1;a:2:{s:29:\"fave_additional_feature_title\";s:18:\"Conductor Material\";s:29:\"fave_additional_feature_value\";s:11:\"Bare Copper\";}i:2;a:2:{s:29:\"fave_additional_feature_title\";s:22:\"Conductor Construction\";s:29:\"fave_additional_feature_value\";s:30:\"Class 2, RE \/ RM \/ SM Variants\";}}"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":["N2XY-O 1x50|565|480\r\nN2XY-O 1x70|775|672\r\nN2XY-O 1x95|980|912\r\nN2XY-O 1x120|1248|1152\r\nN2XY-O 1x150|1538|1440\r\nN2XY-O 1x185|1882|1776\r\nN2XY-O 1x240|2415|2304\r\nN2XY-O 1x300|3000|2880\r\nN2XY-O 1x400|4100|3840\r\nN2XY-O 1x500|4942|4800\r\nN2XY-J 1x150|1500|1440\r\nN2XY-J 1x120|1248|1152\r\nN2XY-J 1x185|1882|1776\r\nN2XY-J 1x240|2415|2304\r\nN2XY-J 3x1.5|190|43.2\r\nN2XY-J 3x2.5|232|72\r\nN2XY-J 3x16|817|461\r\nN2XY-J 4x4|350|154\r\nN2XY-J 4x6|460|230\r\nN2XY-J 4x10|640|384\r\nN2XY-J 4x16|1150|614\r\nN2XY-J 4x25|1420|960\r\nN2XY-J 4x35|1830|1344\r\nN2XY-J 4x50|2040|1920\r\nN2XY-J 4x70|2860|2688\r\nN2XY-J 4x95|4250|3648\r\nN2XY-J 4x120|5300|4608\r\nN2XY-J 5x1.5|246|72\r\nN2XY-J 5x2.5|309|120\r\nN2XY-J 5x4|394|192\r\nN2XY-J 5x6|536|288\r\nN2XY-J 5x25|1735|1200\r\nN2XY-J 8x1.5|305|115\r\nN2XY-J 8x2.5|399|192\r\nN2XY-J 12x1.5|412|173\r\nN2XY-J 12x2.5|549|288\r\nN2XY-J 14x1.5|456|202"],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":["N2XY-J \/ N2XY-O | Copper XLPE\/PVC Power Cable | 0.6\/1 kV | CPR Eca"],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":["N2XY-J \/ N2XY-O is a low voltage copper power cable designed for fixed installation indoors, outdoors, in the ground and in water.\r\n\r\nThe cable features bare copper conductors, Class 2 conductor construction, XLPE insulation and a PVC outer sheath. It is available with a protective conductor (N2XY-J) or without a protective conductor (N2XY-O).\r\n\r\nRated voltage is 0.6\/1 kV, maximum system voltage is 1.2 kV and test voltage is 4 kV. The maximum operating conductor temperature is 90\u00b0C and the maximum short-circuit conductor temperature is 250\u00b0C.\r\n\r\nThe cable is UV-resistant, flame-retardant according to IEC 60332-1-2 and classified Eca according to EN 50575."],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":["Conductor|Bare Copper, Class 2\r\nConductor Shape|Round Solid, Round Stranded or Sector-Shaped Stranded According to Size\r\nCore Insulation|Cross-Linked Polyethylene (XLPE)\r\nCore Identification|VDE 0293 \/ HD 308\r\nProtective Conductor|N2XY-J With PE \/ N2XY-O Without PE\r\nOuter Sheath|Polyvinyl Chloride (PVC)"],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":["VDE 0276-603 \u2013 Low Voltage Power Cable Standard\r\nEN 50575 \u2013 CPR Classification Eca\r\nIEC 60332-1-2 \u2013 Flame Propagation Test\r\nVDE 0293 \/ HD 308 \u2013 Core Identification"],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":["Low Voltage Power Distribution\r\nCommercial Buildings\r\nIndustrial Facilities\r\nFixed Indoor Installations\r\nFixed Outdoor Installations\r\nUnderground Cable Routes\r\nFixed Installation in Water\r\nElectrical Infrastructure\r\nBuilding Power Supply Systems"],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":["Cable Designation|N2XY-J \/ N2XY-O\r\nCable Type|Copper XLPE\/PVC Power Cable\r\nRated Voltage|0.6\/1 kV\r\nMaximum System Voltage|1.2 kV\r\nTest Voltage|4 kV\r\nConductor Material|Bare Copper\r\nConductor Construction|Class 2\r\nInsulation|XLPE\r\nOuter Sheath|PVC\r\nProtective Conductor|J = With PE \/ O = Without PE\r\nCore Identification|VDE 0293 \/ HD 308\r\nMaximum Conductor Temperature|90\u00b0C\r\nMaximum Short-Circuit Temperature|250\u00b0C\r\nPermitted Outer Cable Temperature, Fixed|Maximum +50\u00b0C\r\nPermitted Outer Cable Temperature, Moved|-5\u00b0C to +50\u00b0C\r\nMinimum Bending Radius, Multicore|12 x Outer Diameter\r\nMinimum Bending Radius, Single-Core|15 x Outer Diameter\r\nUV Resistance|Yes\r\nOutdoor Installation|Yes\r\nFlame Retardance|IEC 60332-1-2\r\nCPR Classification|Eca\r\nProduct Standard|VDE 0276-603"],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":["size|resistance20|insulation|sheath|ampacity|outer_diameter|cable_weight\r\nN2XY-O 1x50|0.387|||207|14.7|565\r\nN2XY-O 1x70|0.268|||263|16.6|775\r\nN2XY-O 1x95|0.193|||325|17.9|980\r\nN2XY-O 1x120|0.153|||380|19.4|1248\r\nN2XY-O 1x150|0.124|||437|21.7|1538\r\nN2XY-O 1x185|0.0991|||507|23.3|1882\r\nN2XY-O 1x240|0.0754|||604|26|2415\r\nN2XY-O 1x300|0.0601|||697|29|3000\r\nN2XY-O 1x400|0.047|||811|31.5|4100\r\nN2XY-O 1x500|0.0366|||940|38|4942\r\nN2XY-J 1x150|0.124||||21.5|1500\r\nN2XY-J 1x120|0.153||||19.4|1248\r\nN2XY-J 1x185|0.0991||||23.3|1882\r\nN2XY-J 1x240|0.0754||||26|2415\r\nN2XY-J 3x1.5|12.1|||24|11.4|190\r\nN2XY-J 3x2.5|7.41|||32|12.2|232\r\nN2XY-J 3x16|1.15|||98|18.5|817\r\nN2XY-J 4x4|4.61|||42|14.2|350\r\nN2XY-J 4x6|3.08|||53|15.6|460\r\nN2XY-J 4x10|1.83|||86|17.4|640\r\nN2XY-J 4x16|1.15|||98|21.9|1150\r\nN2XY-J 4x25|0.727|||133|24.8|1420\r\nN2XY-J 4x35|0.524|||162|27.2|1830\r\nN2XY-J 4x50|0.387|||197|28.1|2040\r\nN2XY-J 4x70|0.268|||250|32.5|2860\r\nN2XY-J 4x95|0.193|||308|39|4250\r\nN2XY-J 4x120|0.153|||359|42.5|5300\r\nN2XY-J 5x1.5|12.1|||24|13|246\r\nN2XY-J 5x2.5|7.41|||32|14|309\r\nN2XY-J 5x4|4.61|||42|17|394\r\nN2XY-J 5x6|3.08|||53|19|536\r\nN2XY-J 5x25|0.727|||133|29|1735\r\nN2XY-J 8x1.5|12.1|||24|13.9|305\r\nN2XY-J 8x2.5|7.41|||32|15.1|399\r\nN2XY-J 12x1.5|12.1|||24|16.5|412\r\nN2XY-J 12x2.5|7.41|||32|18|549\r\nN2XY-J 14x1.5|12.1|||24|17.2|456"],"_datasheet_size_data":["field_6ab787279d659"],"_aioseo_title":[null],"_aioseo_description":["N2XY Cable 0.6\/1 kV with copper conductors, XLPE insulation and PVC sheath. Explore N2XY-J and N2XY-O sizes, technical data and weights at UNIMA CABLE."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["6"],"houzez_views_by_date":["a:1:{s:10:\"10-13-2026\";i:6;}"],"houzez_recently_viewed":["2026-10-13 03:20:52"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/4824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/4824\/revisions"}],"predecessor-version":[{"id":4826,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/4824\/revisions\/4826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media\/4825"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=4824"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=4824"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=4824"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=4824"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=4824"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=4824"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=4824"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=4824"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=4824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}