{"id":4821,"date":"2026-10-13T00:12:15","date_gmt":"2026-10-13T00:12:15","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=4821"},"modified":"2026-10-13T00:18:56","modified_gmt":"2026-10-13T00:18:56","slug":"na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/","title":{"rendered":"NA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable 6\/10\u201318\/30 kV"},"content":{"rendered":"\n<div id=\"unima-na2xsf2y-overview\">\n<style>\n#unima-na2xsf2y-overview{\n  --navy:#071a2d;--blue:#0878c9;\n  --line:#dce7ef;--soft:#f3f8fc;\n  font-family:Arial,Helvetica,sans-serif;\n  color:var(--navy);margin:25px 0;line-height:1.65\n}\n#unima-na2xsf2y-overview *{box-sizing:border-box}\n#unima-na2xsf2y-overview .hero{\n  background:linear-gradient(130deg,#071a2d,#123c60);\n  border-radius:14px;padding:32px;color:white\n}\n#unima-na2xsf2y-overview .eyebrow{\n  color:#70c9ff;font-size:11px;font-weight:800;\n  letter-spacing:2px;margin-bottom:10px\n}\n#unima-na2xsf2y-overview .hero h2{\n  color:white;font-size:28px;margin:0 0 12px;\n  line-height:1.3\n}\n#unima-na2xsf2y-overview .hero p{\n  color:#d5e7f5;margin:0;font-size:14px\n}\n#unima-na2xsf2y-overview .tags{\n  display:flex;flex-wrap:wrap;gap:8px;margin-top:20px\n}\n#unima-na2xsf2y-overview .tags span{\n  background:rgba(255,255,255,.09);\n  border:1px solid rgba(255,255,255,.23);\n  border-radius:30px;padding:7px 12px;\n  color:white;font-size:11px;font-weight:700\n}\n#unima-na2xsf2y-overview .section{margin-top:27px}\n#unima-na2xsf2y-overview h3{\n  border-left:5px solid var(--blue);\n  padding-left:12px;font-size:21px;margin:0 0 16px\n}\n#unima-na2xsf2y-overview .intro{\n  border:1px solid var(--line);\n  border-radius:10px;padding:22px;\n  color:#35495c;font-size:14px\n}\n#unima-na2xsf2y-overview .features{\n  display:grid;grid-template-columns:repeat(4,1fr);\n  gap:11px\n}\n#unima-na2xsf2y-overview .feature{\n  background:var(--soft);border:1px solid var(--line);\n  border-radius:10px;padding:20px 12px;text-align:center\n}\n#unima-na2xsf2y-overview .feature strong{\n  display:block;font-size:18px;margin-bottom:5px\n}\n#unima-na2xsf2y-overview .feature small{\n  display:block;color:#5b6d7d;font-size:11px\n}\n#unima-na2xsf2y-overview .panels{\n  display:grid;grid-template-columns:1fr 1fr;gap:16px\n}\n#unima-na2xsf2y-overview .panel{\n  border:1px solid var(--line);\n  border-radius:10px;overflow:hidden\n}\n#unima-na2xsf2y-overview .panel h4{\n  background:#102d48;color:white;\n  padding:15px;margin:0;font-size:15px\n}\n#unima-na2xsf2y-overview .item{\n  display:grid;grid-template-columns:43% 57%;\n  gap:8px;padding:12px 15px;\n  border-bottom:1px solid var(--line);\n  font-size:12px\n}\n#unima-na2xsf2y-overview .item span{color:#607487}\n#unima-na2xsf2y-overview .item b{color:#071a2d}\n#unima-na2xsf2y-overview .applications{\n  display:grid;grid-template-columns:1fr 1fr;gap:10px\n}\n#unima-na2xsf2y-overview .app{\n  background:var(--soft);border:1px solid var(--line);\n  border-radius:8px;padding:14px;font-size:13px\n}\n#unima-na2xsf2y-overview .app:before{\n  content:\"\u2713\";color:var(--blue);\n  font-weight:900;margin-right:10px\n}\n#unima-na2xsf2y-overview .note{\n  margin-top:24px;background:#f5f9fc;\n  border-left:4px solid var(--blue);\n  padding:18px;font-size:12px;color:#43586b\n}\n@media(max-width:700px){\n  #unima-na2xsf2y-overview .features{\n    grid-template-columns:repeat(2,1fr)\n  }\n  #unima-na2xsf2y-overview .panels,\n  #unima-na2xsf2y-overview .applications{\n    grid-template-columns:1fr\n  }\n  #unima-na2xsf2y-overview .hero{padding:24px}\n  #unima-na2xsf2y-overview .hero h2{font-size:22px}\n}\n<\/style>\n\n<div class=\"hero\">\n  <div class=\"eyebrow\">\n    UNIMA CABLE | MEDIUM VOLTAGE SOLUTIONS\n  <\/div>\n  <h2>\n    NA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable\n  <\/h2>\n  <p>\n    Longitudinally watertight single-core aluminium\n    medium voltage power cable with XLPE insulation,\n    copper wire screen and UV-resistant PE outer sheath.\n    Designed for demanding underground, industrial,\n    utility and power distribution installations.\n  <\/p>\n  <div class=\"tags\">\n    <span>6\/10 kV<\/span>\n    <span>12\/20 kV<\/span>\n    <span>18\/30 kV<\/span>\n    <span>VDE 0276-620<\/span>\n    <span>Longitudinal Water Blocking<\/span>\n    <span>UV Resistant<\/span>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Product Overview<\/h3>\n  <div class=\"intro\">\n    <p>\n      <strong>NA2XS(F)2Y<\/strong> is a single-core\n      medium voltage cable with a Class 2 stranded\n      aluminium conductor and XLPE DIX8 insulation.\n      Inner and outer semiconducting layers provide\n      electrical field control through a triple\n      extrusion process.\n    <\/p>\n    <p>\n      The cable includes a copper wire screen with\n      counter helix and a black polyethylene DMP2\n      outer sheath. Longitudinal water blocking\n      reduces water migration along the cable\n      following mechanical damage.\n    <\/p>\n    <p>\n      Suitable for installation in the ground,\n      water, cable ducts, outdoors and indoors.\n      Typical uses include substations, industrial\n      facilities, power stations and electricity\n      distribution networks.\n    <\/p>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Key Technical Features<\/h3>\n  <div class=\"features\">\n    <div class=\"feature\">\n      <strong>Al \/ Class 2<\/strong>\n      <small>Stranded Aluminium Conductor<\/small>\n    <\/div>\n    <div class=\"feature\">\n      <strong>XLPE DIX8<\/strong>\n      <small>Cross-Linked Insulation<\/small>\n    <\/div>\n    <div class=\"feature\">\n      <strong>90\u00b0C<\/strong>\n      <small>Maximum Conductor Temperature<\/small>\n    <\/div>\n    <div class=\"feature\">\n      <strong>15 \u00d7 \u00d8<\/strong>\n      <small>Minimum Fixed Bending Radius<\/small>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Cable Construction &amp; Technical Data<\/h3>\n  <div class=\"panels\">\n    <div class=\"panel\">\n      <h4>Cable Construction<\/h4>\n      <div class=\"item\"><span>Conductor<\/span><b>Aluminium, Class 2 Stranded<\/b><\/div>\n      <div class=\"item\"><span>Insulation<\/span><b>XLPE DIX8<\/b><\/div>\n      <div class=\"item\"><span>Field Control<\/span><b>Inner and Outer Semiconducting Layers<\/b><\/div>\n      <div class=\"item\"><span>Screen<\/span><b>Copper Wires + Counter Helix<\/b><\/div>\n      <div class=\"item\"><span>Water Blocking<\/span><b>Longitudinally Watertight<\/b><\/div>\n      <div class=\"item\"><span>Outer Sheath<\/span><b>Polyethylene DMP2<\/b><\/div>\n      <div class=\"item\"><span>Sheath Colour<\/span><b>Black<\/b><\/div>\n    <\/div>\n    <div class=\"panel\">\n      <h4>Electrical &amp; Mechanical Properties<\/h4>\n      <div class=\"item\"><span>Rated Voltage<\/span><b>6\/10, 12\/20, 18\/30 kV<\/b><\/div>\n      <div class=\"item\"><span>Maximum System Voltage<\/span><b>12 \/ 24 \/ 36 kV<\/b><\/div>\n      <div class=\"item\"><span>Test Voltage<\/span><b>21 \/ 42 \/ 63 kV<\/b><\/div>\n      <div class=\"item\"><span>Conductor Temperature<\/span><b>Maximum 90\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Outer Cable, Fixed<\/span><b>Maximum +70\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Outer Cable, Moving<\/span><b>-20\u00b0C to +70\u00b0C<\/b><\/div>\n      <div class=\"item\"><span>Bending Radius<\/span><b>15 \u00d7 Outer Diameter<\/b><\/div>\n      <div class=\"item\"><span>Partial Discharge<\/span><b>2 pC<\/b><\/div>\n      <div class=\"item\"><span>UV Resistance<\/span><b>Yes<\/b><\/div>\n      <div class=\"item\"><span>Flame Retardance<\/span><b>Not Specified \/ None<\/b><\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Typical Applications<\/h3>\n  <div class=\"applications\">\n    <div class=\"app\">Medium Voltage Distribution Networks<\/div>\n    <div class=\"app\">Electrical Substations<\/div>\n    <div class=\"app\">Solar &amp; Wind Energy Infrastructure<\/div>\n    <div class=\"app\">Industrial Power Installations<\/div>\n    <div class=\"app\">Underground Cable Routes<\/div>\n    <div class=\"app\">Cable Ducts and Outdoor Installations<\/div>\n    <div class=\"app\">Power Stations<\/div>\n    <div class=\"app\">Installations Requiring Longitudinal Water Blocking<\/div>\n  <\/div>\n<\/div>\n\n<div class=\"section\">\n  <h3>Applicable Standard<\/h3>\n  <div class=\"intro\">\n    <strong>VDE 0276-620<\/strong> \u2013 Medium voltage\n    cable construction and technical requirements.\n    Specific electrical and dimensional values\n    depend on the voltage class and cable size.\n  <\/div>\n<\/div>\n\n<div class=\"note\">\n  <strong>Technical Notice:<\/strong>\n  This cable is not described as flame-retardant\n  in the referenced manufacturer datasheet.\n  The PE outer sheath provides mechanical durability\n  and UV resistance. Current ratings depend on\n  installation conditions. Technical values and\n  approximate dimensions should be confirmed\n  for the selected configuration.\n<\/div>\n<\/div>\n\n\n\n<div id=\"unima-na2xsf2y-range\">\n<style>\n#unima-na2xsf2y-range{\n  --navy:#071a2d;--blue:#0878c9;--line:#dce7ef;\n  font-family:Arial,Helvetica,sans-serif;\n  color:var(--navy);margin:25px 0\n}\n#unima-na2xsf2y-range *{box-sizing:border-box}\n#unima-na2xsf2y-range .head{\n  background:var(--navy);color:#fff;\n  padding:25px;border-radius:12px 12px 0 0\n}\n#unima-na2xsf2y-range .head h2{\n  color:white;font-size:24px;margin:0 0 8px\n}\n#unima-na2xsf2y-range .head p{\n  color:#c3d7e7;font-size:13px;margin:0\n}\n#unima-na2xsf2y-range .body{\n  padding:20px;border:1px solid var(--line);\n  border-radius:0 0 12px 12px\n}\n#unima-na2xsf2y-range .stats{\n  display:grid;grid-template-columns:repeat(4,1fr);\n  gap:10px;margin-bottom:20px\n}\n#unima-na2xsf2y-range .stat{\n  background:#f3f8fc;border:1px solid var(--line);\n  border-radius:8px;padding:15px 8px;text-align:center\n}\n#unima-na2xsf2y-range .stat b{\n  display:block;font-size:18px\n}\n#unima-na2xsf2y-range .stat small{\n  color:#607487;font-size:11px\n}\n#unima-na2xsf2y-range .filters{\n  display:flex;gap:10px;flex-wrap:wrap;margin-bottom:16px\n}\n#unima-na2xsf2y-range input,\n#unima-na2xsf2y-range select{\n  flex:1;min-width:180px;padding:12px;\n  border:1px solid #cbdde9;border-radius:8px;\n  background:white;color:#071a2d;font-size:13px\n}\n#unima-na2xsf2y-range .scroll{\n  overflow-x:auto;border:1px solid var(--line);\n  border-radius:9px\n}\n#unima-na2xsf2y-range table{\n  width:100%;min-width:1050px;\n  border-collapse:collapse;margin:0;font-size:12px\n}\n#unima-na2xsf2y-range th{\n  background:#102d48;color:white;\n  padding:13px 9px;text-align:center\n}\n#unima-na2xsf2y-range td{\n  padding:12px 9px;text-align:center;\n  border-bottom:1px solid #e5edf3;white-space:nowrap\n}\n#unima-na2xsf2y-range tbody tr:nth-child(even){\n  background:#f5f9fc\n}\n#unima-na2xsf2y-range tbody tr:hover{\n  background:#eaf5fd\n}\n#unima-na2xsf2y-range td:first-child{\n  font-weight:800;color:#075c9c\n}\n#unima-na2xsf2y-range .foot{\n  margin-top:13px;color:#607487;font-size:12px\n}\n#unima-na2xsf2y-range .note{\n  background:#f5f9fc;border-left:4px solid var(--blue);\n  margin-top:20px;padding:17px;\n  font-size:12px;line-height:1.7;color:#43586b\n}\n@media(max-width:650px){\n  #unima-na2xsf2y-range .stats{\n    grid-template-columns:repeat(2,1fr)\n  }\n}\n<\/style>\n\n<div class=\"head\">\n  <h2>Technical Data &amp; Cable Dimensions<\/h2>\n  <p>\n    NA2XS(F)2Y | Aluminium Medium Voltage Cable |\n    VDE 0276-620\n  <\/p>\n<\/div>\n\n<div class=\"body\">\n  <div class=\"stats\">\n    <div class=\"stat\">\n      <b>3<\/b><small>Voltage Classes<\/small>\n    <\/div>\n    <div class=\"stat\">\n      <b>57<\/b><small>Configurations<\/small>\n    <\/div>\n    <div class=\"stat\">\n      <b>90\u00b0C<\/b><small>Max. Conductor Temp.<\/small>\n    <\/div>\n    <div class=\"stat\">\n      <b>XLPE<\/b><small>Insulation<\/small>\n    <\/div>\n  <\/div>\n\n  <div class=\"filters\">\n    <select class=\"voltage\" aria-label=\"Voltage class\">\n      <option value=\"\">All Voltage Classes<\/option>\n      <option value=\"6\/10\">6\/10 kV<\/option>\n      <option value=\"12\/20\">12\/20 kV<\/option>\n      <option value=\"18\/30\">18\/30 kV<\/option>\n    <\/select>\n    <input type=\"search\" class=\"search\"\n      placeholder=\"Search e.g. 1x240\/25\"\n      aria-label=\"Search cable configuration\">\n  <\/div>\n\n  <div class=\"scroll\">\n    <table>\n      <thead>\n        <tr>\n          <th>Voltage<\/th>\n          <th>Configuration<\/th>\n          <th>Resistance<br>\u03a9\/km<\/th>\n          <th>Insulation<br>mm<\/th>\n          <th>Air<br>A<\/th>\n          <th>Ground<br>A<\/th>\n          <th>Outer \u00d8<br>mm<\/th>\n          <th>Aluminium<br>kg\/km<\/th>\n          <th>Copper<br>kg\/km<\/th>\n          <th>Cable<br>kg\/km<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody class=\"data\"><\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"foot\">\n    <span class=\"count\"><\/span>\n    | Source: Klaus Faber AG\n  <\/div>\n\n  <div class=\"note\">\n    <strong>Technical notes:<\/strong>\n    Air current ratings refer to 30\u00b0C ambient temperature.\n    Ground current ratings refer to 20\u00b0C ground temperature.\n    Values are manufacturer reference data.\n    Outer diameters are approximate.\n    <br><br>\n    <strong>Special variants:<\/strong>\n    Configurations marked &#8220;reinforced&#8221; have a\n    3.0 mm reinforced outer sheath.\n    <br><br>\n    <strong>Installation:<\/strong>\n    Actual current-carrying capacity depends on\n    installation conditions, thermal resistivity,\n    cable grouping and applicable correction factors.\n  <\/div>\n<\/div>\n\n<script>\n(function(){\n  const root=document.getElementById(\n    \"unima-na2xsf2y-range\"\n  );\n  if(!root||root.dataset.initialized===\"1\")return;\n  root.dataset.initialized=\"1\";\n\n  \/*\n  Format:\n  voltage|size|resistance|insulation|\n  air A|ground A|diameter|Al kg\/km|\n  Cu kg\/km|cable kg\/km\n  *\/\n\n  const raw=`\n6\/10|1x50\/16|0.641|3.4|183|171|25|145|182|635\n6\/10|1x70\/16|0.443|3.4|228|208|27|203|182|735\n6\/10|1x95\/16|0.32|3.4|278|248|28|276|182|835\n6\/10|1x120\/16|0.253|3.4|321|283|30|348|182|935\n6\/10|1x150\/25|0.206|3.4|364|315|31|435|283|1118\n6\/10|1x185\/25|0.164|3.4|418|357|33|537|283|1263\n6\/10|1x240\/25|0.125|3.4|494|413|35|696|283|1463\n6\/10|1x300\/25|0.1|3.4|568|466|37|870|283|1687\n6\/10|1x400\/35|0.0778|3.4|660|529|40|1160|394|2096\n6\/10|1x400\/50|0.0778|3.4|660|529|40|1160|560|2200\n6\/10|1x500\/35|0.0605|3.4|767|602|44|1450|394|2477\n6\/10|1x630\/35|0.0469|3.4|890|675|49|1827|394|2969\n6\/10|1x800\/35|0.0367|3.4|1022|733|52|2320|394|3400\n6\/10|1x1000\/35|0.0291|3.4|1151|856|63|2900|394|4780\n12\/20|1x50\/16|0.641|5.5|185|172|29|145|182|784\n12\/20|1x70\/16|0.443|5.5|231|210|31|203|182|902\n12\/20|1x95\/16|0.32|5.5|280|251|32|276|182|1013\n12\/20|1x120\/16|0.253|5.5|323|285|34|348|182|1117\n12\/20|1x150\/16|0.206|5.5|366|319|36|435|182|1254\n12\/20|1x150\/25|0.206|5.5|366|319|36|435|283|1313\n12\/20|1x150\/50|0.206|5.5|366|319|36.4|435|560|1560\n12\/20|1x185\/25|0.164|5.5|420|361|37|537|283|1467\n12\/20|1x240\/25|0.125|5.5|496|417|40|696|283|1682\n12\/20|1x300\/25|0.1|5.5|569|471|42|870|283|1920\n12\/20|1x300\/50|0.1|5.5|569|471|42|870|560|2120\n12\/20|1x400\/35|0.0778|5.5|660|535|45|1160|394|2355\n12\/20|1x500\/35|0.0605|5.5|766|609|48|1450|394|2760\n12\/20|1x500\/50|0.0605|5.5|766|609|48.3|1450|560|2840\n12\/20|1x630\/35|0.0469|5.5|890|675|52|1827|394|3268\n12\/20|1x630\/50|0.0469|5.5|890|675|52.2|1827|560|3320\n12\/20|1x800\/35|0.0367|5.5|1015|750|60|2320|394|3938\n12\/20|1x1000\/35|0.0291|5.5|1135|820|62.6|2900|394|4610\n12\/20|1x1200\/35|0.0247|5.5|1278|998|65|3480|394|5100\n12\/20|1x70\/16 reinforced|0.443|5.5|231|210|31.6|203|182|930\n12\/20|1x150\/25 reinforced|0.206|5.5|366|319|36|435|283|1300\n12\/20|1x240\/25 reinforced|0.125|5.5|496|417|40|696|283|1700\n12\/20|1x630\/35 reinforced|0.0469|5.5|890|675|53.3|1827|394|3200\n18\/30|1x50\/16|0.641|8|187|174|34|145|182|998\n18\/30|1x70\/16|0.443|8|232|213|36|203|182|1128\n18\/30|1x95\/16|0.32|8|282|254|37|276|182|1255\n18\/30|1x95\/35|0.32|8|282|254|37.5|396|396|1420\n18\/30|1x120\/16|0.253|8|325|289|39|348|182|1375\n18\/30|1x120\/35|0.253|8|325|289|39|348|396|1560\n18\/30|1x150\/25|0.206|8|367|322|40|435|283|1573\n18\/30|1x150\/35|0.206|8|367|322|40.5|435|396|1670\n18\/30|1x185\/25|0.164|8|421|364|42|537|283|1740\n18\/30|1x185\/35|0.164|8|421|364|42|537|396|1825\n18\/30|1x240\/25|0.125|8|496|422|44|696|283|1979\n18\/30|1x300\/25|0.1|8|568|476|47|870|283|2221\n18\/30|1x300\/35|0.1|8|568|476|46|870|396|2285\n18\/30|1x400\/35|0.0778|8|659|541|50|1160|394|2674\n18\/30|1x500\/35|0.0605|8|764|616|53|1450|394|3132\n18\/30|1x500\/50|0.0605|8|764|616|54.5|1450|565|3310\n18\/30|1x630\/35|0.0469|8|890|675|60|1827|394|3668\n18\/30|1x800\/35|0.0367|8|1015|750|65|2320|394|4367\n18\/30|1x1000\/35|0.0291|8|1135|820|66|2900|394|4800\n18\/30|1x300\/25 reinforced|0.1|8|568|476|47|870|283|2200\n`;\n\n  const data=raw.trim().split(\"\\n\").map(line=>{\n    const v=line.trim().split(\"|\");\n    return {\n      voltage:v[0],size:v[1],resistance:v[2],\n      insulation:v[3],air:v[4],ground:v[5],\n      diameter:v[6],al:v[7],cu:v[8],weight:v[9]\n    };\n  });\n\n  const tbody=root.querySelector(\".data\");\n  const voltage=root.querySelector(\".voltage\");\n  const search=root.querySelector(\".search\");\n  const count=root.querySelector(\".count\");\n\n  function render(){\n    const term=search.value.toLowerCase()\n      .replace(\/\\s+\/g,\"\").replace(\/\u00d7\/g,\"x\");\n\n    const rows=data.filter(x=>{\n      const name=x.size.toLowerCase()\n        .replace(\/\\s+\/g,\"\");\n      return (!voltage.value||\n        x.voltage===voltage.value) &&\n        name.includes(term);\n    });\n\n    tbody.replaceChildren();\n\n    rows.forEach(x=>{\n      const tr=document.createElement(\"tr\");\n      [\n        x.voltage+\" kV\",x.size,x.resistance,\n        x.insulation,x.air,x.ground,\n        x.diameter,x.al,x.cu,x.weight\n      ].forEach(value=>{\n        const td=document.createElement(\"td\");\n        td.textContent=value;\n        tr.appendChild(td);\n      });\n      tbody.appendChild(tr);\n    });\n\n    if(!rows.length){\n      const tr=document.createElement(\"tr\");\n      const td=document.createElement(\"td\");\n      td.colSpan=10;\n      td.textContent=\"No matching configurations\";\n      tr.appendChild(td);tbody.appendChild(tr);\n    }\n\n    count.textContent=\"Showing \"+rows.length+\n      \" of \"+data.length+\" configurations\";\n  }\n\n  search.addEventListener(\"input\",render);\n  voltage.addEventListener(\"change\",render);\n  render();\n})();\n<\/script>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | MEDIUM VOLTAGE SOLUTIONS NA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable Longitudinally watertight single-core aluminium medium voltage power cable with XLPE insulation, copper wire screen and UV-resistant PE outer sheath. Designed for demanding underground, industrial, utility and power distribution installations. 6\/10 kV 12\/20 kV 18\/30 kV VDE 0276-620 Longitudinal Water Blocking UV Resistant Product [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4822,"parent":0,"menu_order":0,"template":"","property_type":[47],"property_status":[],"property_feature":[],"property_label":[75,62,98,74],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-4821","property","type-property","status-publish","has-post-thumbnail","hentry","property_type-power-cables-1-30-kv","property_label-batery-storage","property_label-solar-energy","property_label-waterfront","property_label-wind-energy"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA\" \/>\n\t\t<meta property=\"og:description\" content=\"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-13T00:12:15+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-13T00:18:56+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA\" \/>\n\t\t<meta name=\"twitter:description\" content=\"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"name\":\"Power cables 1 - 30 kV\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"position\":3,\"name\":\"Power cables 1 - 30 kV\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#listItem\",\"name\":\"NA2XS(F)2Y \\u2013 Aluminium Medium Voltage Cable 6\\\/10\\u201318\\\/30 kV\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#listItem\",\"position\":4,\"name\":\"NA2XS(F)2Y \\u2013 Aluminium Medium Voltage Cable 6\\\/10\\u201318\\\/30 kV\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables-1-30-kv\\\/#listItem\",\"name\":\"Power cables 1 - 30 kV\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/\",\"name\":\"NA2XS(F)2Y Cable \\u2013 Aluminium MV Cable \\\\| UNIMA\",\"description\":\"NA2XS(F)2Y Cable for 6\\\/10, 12\\\/20 and 18\\\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Untitled-design-53.png\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#mainImage\",\"width\":500,\"height\":500},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\\\/#mainImage\"},\"datePublished\":\"2026-10-13T00:12:15+00:00\",\"dateModified\":\"2026-10-13T00:18:56+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA","description":"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","name":"Power cables 1 - 30 kV"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","position":3,"name":"Power cables 1 - 30 kV","item":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#listItem","name":"NA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable 6\/10\u201318\/30 kV"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#listItem","position":4,"name":"NA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable 6\/10\u201318\/30 kV","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/#listItem","name":"Power cables 1 - 30 kV"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/","name":"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA","description":"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/unima-cable.com\/wp-content\/uploads\/2026\/10\/Untitled-design-53.png","@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#mainImage","width":500,"height":500},"primaryImageOfPage":{"@id":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/#mainImage"},"datePublished":"2026-10-13T00:12:15+00:00","dateModified":"2026-10-13T00:18:56+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA","og:description":"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.","og:url":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/","article:published_time":"2026-10-13T00:12:15+00:00","article:modified_time":"2026-10-13T00:18:56+00:00","twitter:card":"summary_large_image","twitter:title":"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA","twitter:description":"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking."},"aioseo_meta_data":{"post_id":"4821","title":"NA2XS(F)2Y Cable \u2013 Aluminium MV Cable \\| UNIMA","description":"NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-10-13 00:12:15","updated":"2026-10-13 01:06:00"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/\" title=\"Power cables 1 - 30 kV\">Power cables 1 - 30 kV<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tNA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable 6\/10\u201318\/30 kV\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Power cables 1 - 30 kV","link":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables-1-30-kv\/"},{"label":"NA2XS(F)2Y \u2013 Aluminium Medium Voltage Cable 6\/10\u201318\/30 kV","link":"https:\/\/unima-cable.com\/hr\/property\/na2xsf2y-aluminium-medium-voltage-cable-6-10-18-30-kv\/"}],"property_meta":{"_edit_lock":["1791850737:1"],"_thumbnail_id":["4822"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_cable-type":["NA2XS(F)2Y"],"fave_application":["Power Distribution, Utilities, Substations & Renewable Energy"],"fave_conductor-material":["Aluminium, Class 2 Stranded"],"fave_insulation-material":["XLPE DIX8"],"fave_rated-voltage":["6\/10 kV; 12\/20 kV; 18\/30 kV"],"fave_cpr-class":["Verify Applicable Manufacturer DoP"],"fave_standard":["VDE 0276-620"],"fave_packaging":["Wooden Drums \u2013 On Request"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"additional_features":["a:9:{i:0;a:2:{s:29:\"fave_additional_feature_title\";s:14:\"Cable Function\";s:29:\"fave_additional_feature_value\";s:33:\"Medium Voltage Power Distribution\";}i:1;a:2:{s:29:\"fave_additional_feature_title\";s:18:\"Conductor Material\";s:29:\"fave_additional_feature_value\";s:9:\"Aluminium\";}i:2;a:2:{s:29:\"fave_additional_feature_title\";s:22:\"Conductor Construction\";s:29:\"fave_additional_feature_value\";s:16:\"Class 2 Stranded\";}i:3;a:2:{s:29:\"fave_additional_feature_title\";s:10:\"Insulation\";s:29:\"fave_additional_feature_value\";s:9:\"XLPE DIX8\";}i:4;a:2:{s:29:\"fave_additional_feature_title\";s:24:\"Electrical Field Control\";s:29:\"fave_additional_feature_value\";s:37:\"Inner and Outer Semiconducting Layers\";}i:5;a:2:{s:29:\"fave_additional_feature_title\";s:12:\"Outer Sheath\";s:29:\"fave_additional_feature_value\";s:17:\"Polyethylene DMP2\";}i:6;a:2:{s:29:\"fave_additional_feature_title\";s:13:\"Sheath Colour\";s:29:\"fave_additional_feature_value\";s:5:\"Black\";}i:7;a:2:{s:29:\"fave_additional_feature_title\";s:13:\"Rated Voltage\";s:29:\"fave_additional_feature_value\";s:21:\"6\/10, 12\/20, 18\/30 kV\";}i:8;a:2:{s:29:\"fave_additional_feature_title\";s:22:\"Maximum System Voltage\";s:29:\"fave_additional_feature_value\";s:15:\"12 \/ 24 \/ 36 kV\";}}"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":["6\/10 kV 1x50\/16|635|182\r\n6\/10 kV 1x70\/16|735|182\r\n6\/10 kV 1x95\/16|835|182\r\n6\/10 kV 1x120\/16|935|182\r\n6\/10 kV 1x150\/25|1118|283\r\n6\/10 kV 1x185\/25|1263|283\r\n6\/10 kV 1x240\/25|1463|283\r\n6\/10 kV 1x300\/25|1687|283\r\n6\/10 kV 1x400\/35|2096|394\r\n6\/10 kV 1x400\/50|2200|560\r\n6\/10 kV 1x500\/35|2477|394\r\n6\/10 kV 1x630\/35|2969|394\r\n6\/10 kV 1x800\/35|3400|394\r\n6\/10 kV 1x1000\/35|4780|394\r\n12\/20 kV 1x50\/16|784|182\r\n12\/20 kV 1x70\/16|902|182\r\n12\/20 kV 1x95\/16|1013|182\r\n12\/20 kV 1x120\/16|1117|182\r\n12\/20 kV 1x150\/16|1254|182\r\n12\/20 kV 1x150\/25|1313|283\r\n12\/20 kV 1x150\/50|1560|560\r\n12\/20 kV 1x185\/25|1467|283\r\n12\/20 kV 1x240\/25|1682|283\r\n12\/20 kV 1x300\/25|1920|283\r\n12\/20 kV 1x300\/50|2120|560\r\n12\/20 kV 1x400\/35|2355|394\r\n12\/20 kV 1x500\/35|2760|394\r\n12\/20 kV 1x500\/50|2840|560\r\n12\/20 kV 1x630\/35|3268|394\r\n12\/20 kV 1x630\/50|3320|560\r\n12\/20 kV 1x800\/35|3938|394\r\n12\/20 kV 1x1000\/35|4610|394\r\n12\/20 kV 1x1200\/35|5100|394\r\n12\/20 kV 1x70\/16 reinforced|930|182\r\n12\/20 kV 1x150\/25 reinforced|1300|283\r\n12\/20 kV 1x240\/25 reinforced|1700|283\r\n12\/20 kV 1x630\/35 reinforced|3200|394\r\n18\/30 kV 1x50\/16|998|182\r\n18\/30 kV 1x70\/16|1128|182\r\n18\/30 kV 1x95\/16|1255|182\r\n18\/30 kV 1x95\/35|1420|396\r\n18\/30 kV 1x120\/16|1375|182\r\n18\/30 kV 1x120\/35|1560|396\r\n18\/30 kV 1x150\/25|1573|283\r\n18\/30 kV 1x150\/35|1670|396\r\n18\/30 kV 1x185\/25|1740|283\r\n18\/30 kV 1x185\/35|1825|396\r\n18\/30 kV 1x240\/25|1979|283\r\n18\/30 kV 1x300\/25|2221|283\r\n18\/30 kV 1x300\/35|2285|396\r\n18\/30 kV 1x400\/35|2674|394\r\n18\/30 kV 1x500\/35|3132|394\r\n18\/30 kV 1x500\/50|3310|565\r\n18\/30 kV 1x630\/35|3668|394\r\n18\/30 kV 1x800\/35|4367|394\r\n18\/30 kV 1x1000\/35|4800|394\r\n18\/30 kV 1x300\/25 reinforced|2200|283"],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":["NA2XS(F)2Y | Aluminium Medium Voltage Power Cable | 6\/10\u201318\/30 kV | Longitudinally Watertight"],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":["NA2XS(F)2Y is a longitudinally watertight single-core aluminium medium voltage power cable designed for power distribution networks, substations, power stations and industrial installations.\r\n\r\nThe cable features a Class 2 stranded aluminium conductor, XLPE DIX8 insulation, inner and outer semiconducting layers, copper wire screen with counter helix and a black UV-resistant polyethylene DMP2 outer sheath.\r\n\r\nSuitable for installation underground, in water, outdoors, indoors and in cable ducts. The cable is designed to reduce longitudinal water penetration following mechanical damage.\r\n\r\nAvailable in rated voltage classes 6\/10 kV, 12\/20 kV and 18\/30 kV according to VDE 0276-620."],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":["Conductor|Aluminium, Class 2 Stranded\r\nConductor Screen|Inner Semiconducting Layer\r\nInsulation|XLPE Compound DIX8\r\nInsulation Screen|Outer Semiconducting Layer\r\nElectrical Field Control|Triple Extrusion\r\nMetallic Screen|Copper Wires with Counter Helix\r\nWater Blocking|Longitudinally Watertight\r\nOuter Sheath|Polyethylene Compound DMP2\r\nSheath Colour|Black"],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":["VDE 0276-620 \u2013 Medium Voltage Power Cables"],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":["Cable Designation|NA2XS(F)2Y\r\nConductor Material|Aluminium\r\nConductor Construction|Class 2 Stranded\r\nInsulation|XLPE DIX8\r\nElectrical Field Control|Triple Extruded Semiconducting Layers\r\nMetallic Screen|Copper Wires with Counter Helix\r\nOuter Sheath|Polyethylene DMP2\r\nSheath Colour|Black\r\nLongitudinal Water Blocking|Yes\r\nRated Voltage Classes|6\/10 kV, 12\/20 kV, 18\/30 kV\r\nMaximum System Voltage|12 kV, 24 kV, 36 kV\r\nTest Voltage|21 kV, 42 kV, 63 kV\r\nMaximum Conductor Temperature|90\u00b0C\r\nMaximum Outer Cable Temperature, Fixed|+70\u00b0C\r\nOuter Cable Temperature, Moving|-20\u00b0C to +70\u00b0C\r\nMinimum Bending Radius|15 x Outer Diameter\r\nPartial Discharge|2 pC\r\nUV Resistant|Yes\r\nFlame Retardance|None Specified\r\nProduct Standard|VDE 0276-620"],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":["Cable Designation|NA2XS(F)2Y\r\nCable Type|Longitudinally Watertight Medium Voltage Power Cable\r\nConductor Material|Aluminium\r\nConductor Construction|Class 2 Stranded\r\nConductor Screen|Semiconducting Layer\r\nInsulation|XLPE DIX8\r\nInsulation Screen|Semiconducting Layer\r\nElectrical Field Control|Triple Extrusion\r\nMetallic Screen|Copper Wires with Counter Helix\r\nWater Blocking|Longitudinally Watertight\r\nOuter Sheath|Polyethylene DMP2\r\nSheath Colour|Black\r\nRated Voltage Classes|6\/10 kV, 12\/20 kV, 18\/30 kV\r\nMaximum System Voltage|12 \/ 24 \/ 36 kV\r\nTest Voltage|21 \/ 42 \/ 63 kV\r\nMaximum Conductor Temperature|90\u00b0C\r\nMaximum Outer Cable Temperature, Fixed|+70\u00b0C\r\nOuter Cable Temperature, Moving|-20\u00b0C to +70\u00b0C\r\nMinimum Bending Radius|15 x Outer Diameter\r\nPartial Discharge|2 pC\r\nUV Resistance|Yes\r\nFlame Retardance|Not Specified\r\nProduct Standard|VDE 0276-620"],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":["size|resistance20|insulation|sheath|ampacity|outer_diameter|cable_weight\r\n6\/10 kV 1x50\/16|0.641|3.4|||25|635\r\n6\/10 kV 1x70\/16|0.443|3.4|||27|735\r\n6\/10 kV 1x95\/16|0.32|3.4|||28|835\r\n6\/10 kV 1x120\/16|0.253|3.4|||30|935\r\n6\/10 kV 1x150\/25|0.206|3.4|||31|1118\r\n6\/10 kV 1x185\/25|0.164|3.4|||33|1263\r\n6\/10 kV 1x240\/25|0.125|3.4|||35|1463\r\n6\/10 kV 1x300\/25|0.1|3.4|||37|1687\r\n6\/10 kV 1x400\/35|0.0778|3.4|||40|2096\r\n6\/10 kV 1x400\/50|0.0778|3.4|||40|2200\r\n6\/10 kV 1x500\/35|0.0605|3.4|||44|2477\r\n6\/10 kV 1x630\/35|0.0469|3.4|||49|2969\r\n6\/10 kV 1x800\/35|0.0367|3.4|||52|3400\r\n6\/10 kV 1x1000\/35|0.0291|3.4|||63|4780\r\n12\/20 kV 1x50\/16|0.641|5.5|||29|784\r\n12\/20 kV 1x70\/16|0.443|5.5|||31|902\r\n12\/20 kV 1x95\/16|0.32|5.5|||32|1013\r\n12\/20 kV 1x120\/16|0.253|5.5|||34|1117\r\n12\/20 kV 1x150\/16|0.206|5.5|||36|1254\r\n12\/20 kV 1x150\/25|0.206|5.5|||36|1313\r\n12\/20 kV 1x150\/50|0.206|5.5|||36.4|1560\r\n12\/20 kV 1x185\/25|0.164|5.5|||37|1467\r\n12\/20 kV 1x240\/25|0.125|5.5|||40|1682\r\n12\/20 kV 1x300\/25|0.1|5.5|||42|1920\r\n12\/20 kV 1x300\/50|0.1|5.5|||42|2120\r\n12\/20 kV 1x400\/35|0.0778|5.5|||45|2355\r\n12\/20 kV 1x500\/35|0.0605|5.5|||48|2760\r\n12\/20 kV 1x500\/50|0.0605|5.5|||48.3|2840\r\n12\/20 kV 1x630\/35|0.0469|5.5|||52|3268\r\n12\/20 kV 1x630\/50|0.0469|5.5|||52.2|3320\r\n12\/20 kV 1x800\/35|0.0367|5.5|||60|3938\r\n12\/20 kV 1x1000\/35|0.0291|5.5|||62.6|4610\r\n12\/20 kV 1x1200\/35|0.0247|5.5|||65|5100\r\n12\/20 kV 1x70\/16 reinforced|0.443|5.5|3.0||31.6|930\r\n12\/20 kV 1x150\/25 reinforced|0.206|5.5|3.0||36|1300\r\n12\/20 kV 1x240\/25 reinforced|0.125|5.5|3.0||40|1700\r\n12\/20 kV 1x630\/35 reinforced|0.0469|5.5|3.0||53.3|3200\r\n18\/30 kV 1x50\/16|0.641|8.0|||34|998\r\n18\/30 kV 1x70\/16|0.443|8.0|||36|1128\r\n18\/30 kV 1x95\/16|0.32|8.0|||37|1255\r\n18\/30 kV 1x95\/35|0.32|8.0|||37.5|1420\r\n18\/30 kV 1x120\/16|0.253|8.0|||39|1375\r\n18\/30 kV 1x120\/35|0.253|8.0|||39|1560\r\n18\/30 kV 1x150\/25|0.206|8.0|||40|1573\r\n18\/30 kV 1x150\/35|0.206|8.0|||40.5|1670\r\n18\/30 kV 1x185\/25|0.164|8.0|||42|1740\r\n18\/30 kV 1x185\/35|0.164|8.0|||42|1825\r\n18\/30 kV 1x240\/25|0.125|8.0|||44|1979\r\n18\/30 kV 1x300\/25|0.1|8.0|||47|2221\r\n18\/30 kV 1x300\/35|0.1|8.0|||46|2285\r\n18\/30 kV 1x400\/35|0.0778|8.0|||50|2674\r\n18\/30 kV 1x500\/35|0.0605|8.0|||53|3132\r\n18\/30 kV 1x500\/50|0.0605|8.0|||54.5|3310\r\n18\/30 kV 1x630\/35|0.0469|8.0|||60|3668\r\n18\/30 kV 1x800\/35|0.0367|8.0|||65|4367\r\n18\/30 kV 1x1000\/35|0.0291|8.0|||66|4800\r\n18\/30 kV 1x300\/25 reinforced|0.1|8.0|3.0||47|2200"],"_datasheet_size_data":["field_6ab787279d659"],"_aioseo_title":["NA2XS(F)2Y Cable \u2013 Aluminium MV Cable | UNIMA"],"_aioseo_description":["NA2XS(F)2Y Cable for 6\/10, 12\/20 and 18\/30 kV power distribution. Aluminium conductor, XLPE insulation, copper screen and longitudinal water blocking."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["7"],"houzez_views_by_date":["a:1:{s:10:\"10-13-2026\";i:7;}"],"houzez_recently_viewed":["2026-10-13 02:29:57"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/4821","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/4821\/revisions"}],"predecessor-version":[{"id":4823,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/4821\/revisions\/4823"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media\/4822"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=4821"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=4821"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=4821"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=4821"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=4821"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=4821"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=4821"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=4821"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=4821"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}