UNIMA CABLE
UNIMA CABLE | TECHNICAL DOCUMENTATION

JE-H(St)H FE180/E30-E90

TECHNICAL DATA SHEET

JE-H(St)H FE180/E30-E90 | Halogen-Free Screened Fire Resistant Signal Cable | 225 V Peak

JE-H(St)H FE180/E30-E90
PRODUCT DESCRIPTION

JE-H(St)H FE180/E30-E90 is a halogen-free, screened fire-resistant signal and communication cable with solid copper conductors (0.8 mm), FRNC HI1 insulation, foil screening with drain wire and a red FRNC HM2 outer sheath.

Designed for fixed installation in fire alarm, fire detection and safety communication systems in public, commercial and industrial buildings.

The cable provides FE180 fire resistance and E30-E90 circuit integrity when installed with an appropriately tested cable support system in accordance with DIN 4102-12. Maximum peak operating voltage is 225 V.

CABLE CONSTRUCTION
ConductorBare copper, Class 1 solid, 0.8 mm diameter
Core InsulationFire-resistant halogen-free FRNC compound, HI1
Core ArrangementConductors twisted into pairs; pairs arranged in layers or sub-units
Core IdentificationColour coding according to VDE 0815
ScreenOverall foil screen with drain wire
Outer SheathHalogen-free flame-retardant FRNC compound, HM2
Sheath ColourRed
TECHNICAL DATA
Cable DesignationJE-H(St)H FE180/E30-E90
Peak Operating Voltage225 V
Materijal vodičaBare Copper
Conductor ConstructionClass 1 Solid
Conductor Diameter0.8 mm
Core InsulationFRNC HI1
ScreeningOverall Foil Screen with Drain Wire
Outer SheathFRNC HM2
Sheath ColourRed
Maximum Operating Capacitance120 nF/km
Fixed Installation Temperature-5°C to +50°C
Minimum Bending Radius7.5 x Outer Diameter
Fire ResistanceFE180
Circuit IntegrityE30-E90 (Tested Installation System)
Halogen-FreeIEC 60754
Smoke EmissionIEC 61034
Flame PropagationIEC 60332-3-24
CPR ClassificationAccording to Applicable Manufacturer DoP
Product StandardVDE 0815
STANDARDS
  • VDE 0815 – Cable construction and core identification
  • DIN 4102-12 – E30-E90 circuit integrity in tested installation systems
  • FE180 – Fire resistance classification
  • IEC 60332-3-24 – Flame propagation test
  • IEC 61034 – Smoke density
  • IEC 60754 – Halogen and acidic gas emissions
APPLICATIONS
  • Fire alarm and fire detection systems
  • Fire safety signal transmission
  • Emergency communication systems
  • Public buildings with high fire safety requirements
  • Hospitals and healthcare facilities
  • Schools and educational buildings
  • Commercial and industrial facilities
  • Fixed installation in dry and damp indoor areas
  • Certified cable support systems requiring E30-E90 circuit integrity