UNIMA CABLE
UNIMA CABLE | TECHNICAL DOCUMENTATION

H05VV-F

TECHNICAL DATA SHEET

H05VV-F | Flexible PVC Insulated and Sheathed Cord | 300/500 V | Class 5 Copper

H05VV-F
PRODUCT DESCRIPTION

H05VV-F is a flexible PVC insulated and sheathed cord rated 300/500 V, designed for medium mechanical stress in household, kitchen and office environments.

The cable features bare copper Class 5 fine-stranded conductors, PVC YI2 core insulation and a PVC YM2 outer sheath.

Suitable for connecting household electrical appliances, including appliances in damp rooms. Cooking and heating devices may be connected provided the cable does not touch hot parts or receive direct heat radiation.

The maximum conductor temperature is 60°C. The cable is flame-retardant according to IEC 60332-1-2 and is not suitable for permanent outdoor use.

CABLE CONSTRUCTION
ConductorBare Copper, Class 5 Fine Stranded
Core InsulationPVC Compound YI2
Core IdentificationColours According to VDE 0293 / HD 308
Outer SheathPVC Compound YM2
Available Sheath ColoursBlack, White and Grey Depending on Variant
Protective ConductorG = With Protective Conductor / X = Without Protective Conductor
TECHNICAL DATA
Cable DesignationH05VV-F
Tip kabelaFlexible PVC Insulated Cord
Radni napon300/500 V
Test Voltage2 kV
Materijal vodičaBare Copper
Conductor ConstructionClass 5 Fine Stranded
Core InsulationPVC YI2
Outer SheathPVC YM2
Core IdentificationVDE 0293 / HD 308
Maximum Conductor Temperature60°C
Maximum Outer Cable Temperature, Fixed+50°C
Permitted Outer Cable Temperature, Moved+5°C to +50°C
Minimum Bending Radius, Fixed3 x Outer Diameter
Minimum Bending Radius, Moving5 x Outer Diameter
Flame RetardanceIEC 60332-1-2
Permanent Outdoor InstallationNot Suitable
Product StandardDIN EN 50525-2-11
STANDARDS
  • DIN EN 50525-2-11 – PVC Insulated Flexible Cords
  • DIN EN IEC 60228 – Class 5 Copper Conductors
  • IEC 60332-1-2 – Flame Propagation Test
  • VDE 0293 / HD 308 – Core Identification
APPLICATIONS
  • Household Electrical Appliances
  • Kitchen Appliances
  • Office Electrical Equipment
  • Indoor Flexible Power Connections
  • Electrical Appliances in Damp Rooms
  • Cooking and Heating Devices Without Direct Heat Contact
  • Connections Subject to Medium Mechanical Stress
  • Not Suitable for Permanent Outdoor Use